Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)
Fabric OS Message Reference 133
53-1000437-01
FCR-1066
20
Probable Cause Indicates that another port on the switch is connected to the same edge fabric with a different
fabric ID assignment.
Recommended
Action
Change the port fabric ID to same value as the other ports connected to the edge fabric using the
portCfgExport or portCfgVexport commands.
Severity ERROR
FCR-1066
Message <timestamp>, [FCR-1066], <sequence-number>,, ERROR, <system-name>, Fabric on port
<port number> has the same fabric ID as another fabric.
Probable Cause Indicates that either the fabric split, or there is another fabric (possibly the backbone) that has the
same fabric ID as the fabric connected to the specified port.
Recommended
Action
If the fabric split, then merge the fabrics and manually re-enable the port.
If there is another fabric with the same ID, change the fabric ID for the port using the portCfgExport
or portCfgVExport commands.
Severity ERROR
FCR-1067
Message <timestamp>, [FCR-1067], <sequence-number>,, WARNING, <system-name>, Zone
configurations, total LSAN zones and aliases, exceeded on port <port number> by
<overflow> entries; max entries: <LSAN zone limit>.
Probable Cause Indicates that the total number of zone configurations created in the connected fabric exceeds the
maximum number supported by the Fibre Channel.
The limit includes both active and configured information that is part of the zoning database in the
edge fabric. Non-LSAN zones are not counted in the limit.
Recommended
Action
Limit the logical storage area network (LSAN) zoning related zone configuration in the edge fabric
connected to this port.
Severity WARNING
FCR-1068
Message <timestamp>, [FCR-1068], <sequence-number>,, INFO, <system-name>, The FC Routing
service is disabled.
Probable Cause Indicates that the FC Routing service is disabled. This is caused by fosConfig –-disable fcr,
configDefault, or a configDownload with the fcrState set to 2 (disabled). Note that the FC Routing
service is disabled by the factory.
Recommended
Action
No action is required.