Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

Fabric OS Message Reference 467
53-1001157-01
Chapter
76
SNMP System Messages
SNMP-1001
Message <timestamp>, [SNMP-1001], <sequence-number>,, ERROR, <system-name>, SNMP service
is not available <Reason>.
Probable Cause Indicates the simple network management protocol (SNMP) service could not be started because
of the specified Reason. You will not be able to query the switch through SNMP.
Recommended
Action
Verify the IP address for the Ethernet and Fibre Channel interface is set correctly. If the specified
Reason is an initialization failure, the switch requires a reboot.
Severity ERROR
SNMP-1002
Message <timestamp>, [SNMP-1002], <sequence-number>,, ERROR, <system-name>, SNMP <Error
Details> initialization failed.
Probable Cause Indicates the initialization of the simple network management protocol (SNMP) service failed and
you will not be able to query the switch through SNMP.
Recommended
Action
Reboot or power cycle the switch. This will automatically initialize SNMP.
Severity ERROR
SNMP-1003
Message <timestamp>, [SNMP-1003], <sequence-number>,, ERROR, <system-name>, Distribution
of Community Strings to Secure Fabric failed.
Probable Cause Indicates that the changes in the simple network management protocol (SNMP) community strings
could not be propagated to other switches in the secure fabric.
Recommended
Action
Retry changing the SNMP community strings from the primary switch.
Severity ERROR