Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

64-2 Fabric OS Message Reference
Publication Number: 53-1000242-01
SYSM-1003
64
SYSM-1003
Message
Probable
Cause
Indicates that the user executed the switchStart or switchReboot command. This indicates that all
services are brought back up after a temporary shutdown of that logical switch.
Recommended
Action
No action is required if the switchStart command was executed intentionally. Because reinitializing a
switch is a disruptive operation and can stop I/O traffic, you might have to stop and restart the traffic
during this process.
Severity INFO
SYSM-1004
Message
Probable
Cause
Indicates that there was a failure to read configuration data from the WWN card.
Recommended
Action
Verify that the WWN card is present and operational and that the affected CP is properly seated in its
slot.
Severity ERROR
SYSM-1005
Message
Probable
Cause
Indicates that there was a failure to read the chassis type from the system.
Recommended
Action
Verify that the CP blade is operational and is properly seated in its slot.
Severity CRITICAL
<timestamp>, [SYSM-1003], <sequence-number>,, INFO, <system-name>,
<number>, Switch: <start reason>
<timestamp>, [SYSM-1004], <sequence-number>,, ERROR, <system-name>,
Failed to retrieve current chassis configuration option,
ret=<Unknown>
<timestamp>, [SYSM-1005], <sequence-number>, FFDC, CRITICAL,
<system-name>, CP blade in slot <Slot number> failed to retrieve
current chassis type.