Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)
Fabric OS Message Reference 29-1
Publication Number: 53-1000242-01
Chapter
29
HLO System Messages
HLO-1001
Message
Probable
Cause
Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The
Brocade switch will not accept FSPF frames from the remote switch.
In the Fabric OS, the HLO dead timeout value is not configurable, so this error can only occur when the
Brocade switch is connected to a switch from another manufacturer.
Recommended
Action
The dead timeout value of the remote switch must be compatible with the value specified in the FSPF
protocol. Refer to documentation of the other manufacturer's switch to change this value.
Severity ERROR
HLO-1002
Message
Probable
Cause
Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The
Brocade switch will not accept FSPF frames from the remote switch.
In the Fabric OS, the HLO timeout value is not configurable, so this error can only occur when the
Brocade switch is connected to a switch from another manufacturer.
Recommended
Action
The HLO timeout value of the remote switch must be compatible with the value specified in the FSPF
protocol. Refer to documentation of the other manufacturer's switch to change this value.
Severity ERROR
<timestamp>, [HLO-1001], <sequence-number>, FFDC, ERROR, <system-
name>, Incompatible Inactivity timeout <dead timeout> from port
<port number>, correct value <value>
<timestamp>, [HLO-1002], <sequence-number>, FFDC, ERROR, <system-
name>, Incompatible Hello timeout <HLO timeout> from port <port
number>, correct value <correct value>