Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
466 Fabric OS Command Reference
53-1000599-02
portCfgShow
2
Notes The output of this command may vary depending on the hardware platform and port type.
The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands This command supports the following port options:
slot For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).
[ge]port Specifies the number of the port to be configured, relative to its slot for
bladed systems. For GigE ports, the ports are numbered ge0 - ge1. Use the
switchShow command for a list of valid ports.
Use portCfgshow with one of the following options and optional arguments to display specific
FCIP-related parameters configured for a gigabit Ethernet port:
arp Displays the address resolution protocol (ARP) table.
ipif Displays the IP interface for both ports of the tunnel. IPv6 addresses are
supported.
iproute Displays the IP route on the specified GbE port. IPv6 addresses are
supported.
mode Displays the mode of the specified GbE port. FCIP or not configured.
vlantag Displays VLAN Tagging configuration.
fciptunnel Displays FCIP tunnels on the specified GbE port. Valid arguments for
fciptunnel include.
all | tunnel_id Display includes all FCIP tunnels on the port or the specified FCIP tunnel only.
Valid values for tunnel_id are 0-7.
-ipsec Displays IKE and IPSec policy information on IPSec-enabled tunnels. This
argument is optional.
-qosmap Displays the VC to QoS mapping. This argument is optional.
Examples To display the port configuration settings on an enterprise-class platform:
switch:admin> portcfgshow
Ports of Slot 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+--+--+--+--+---+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
AL_PA Offset 13 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
QOS E_Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
EX Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Mirror Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..