Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
112 Fabric OS Command Reference
53-1000599-02
diagStopBurnin
2
diagStopBurnin
Terminates a blade burn-in run.
Synopsis diagstopburnin [--slot number]
Description Use this command to determine which PID is running burn-in on a blade and terminate that activity.
The burn-in script handles the logging cleanup.
This command does not require a reboot to take effect.
Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands This command has the following operands:
--slot number Specify the slot on which to stop burn-in. If no slot is specified, this command
executes on all slots in the logical switch. This operand is optional.
Examples To stop burn-in mode on a switch:
switch:admin> diagstopburnin --slot 1
No burn-in script active on slot 1
1 burninErrShow output:
0x1eea (fabos): Dec 19 14:42:18
Switch: 0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ...
Err# 0140042 0100:101:000:001:24:37:
0xc84 (fabos): Dec 20 08:57:27
Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ...
Err# 0140042 0100:101:000:000:25:41:
0x1b61 (fabos): Feb 07 19:02:28
Switch: 0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ...
Err# 0140042 0100:101:000:001:26:39:
0x47ff (fabos): Feb 07 21:45:36
Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ...
Err# 0140042 0100:101:000:002:26:41:1N
See Also diagSetBurnin