HP StorageWorks 3800ux/7100ux Optical Jukebox Conversion Guide (AA969-96003, May 2004)

Installation
28 HP StorageWorks 3800ux/7100ux Optical Jukebox Setup Guide
For a 10-drive jukebox, HP recommends one HBA per bus. This would
require attaching two SCSI cables between the host and the jukebox, If the
customer is limited to just one HBA, then the two busses must be
daisy-chained together (see Figure 12).
Figure 12: Daisy-chaining 2 busses with a single HBA
Note: The maximum cable length for LVDS is 12 meters. The maximum cable length for
SE is 3 meters.
WARNING: This product can only be used with an HP approved power cord
for your specific geographic region. Use of a non-HP approved power cord
may result in: 1) noncompliance with individual, country-specific safety
requirements; 2) insufficient conductor ampacity that could result in
overheating with potential personal injury and/or property damage; and 3) a
fractured power cord which could cause the internal contacts to be exposed,
which potentially could subject the user to a shock hazard. HP disclaims all
liability when HP approved power cords are not used.
3. Plug the socket end of the power cord into the power receptacle on the bottom
of the power distribution assembly (see Figure 13).
4. Route the power cord through the clip and close it securely around the cord
(see Figure 13).
5. Continue routing down through the long cable slot at the bottom of the right
side panel, and out through the access hole at the lower back of the jukebox
(see Figure 13).
Terminator
Daisy-chain cable
SCSI cable to host