HP StorageWorks 2012sa Modular Smart Array firmware release notes Version J300P10-01 Part number: 508849-001 First edition: November 2008
Version: J300P10-01 Description These release notes are for the firmware indicated above. This release corrects issues found during product qualification testing after the initial product release. Update recommendation This release is considered Critical. HP strongly recommends this firmware update be installed as soon as possible. This release incorporates significant improvements and fixes.
can impact the upgrade process. Selecting a period of low I/O activity will ensure the upgrade completes as quickly as possible, and will avoid disruptions to hosts and applications due to timeouts. • Caution: Before upgrading the controller firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If any configurations changes are in progress, monitor them using the SMU and wait until they are completed before proceeding with the upgrade.
6. Select your Windows Server 2003 operating system. 7. In the Operating System — Enhancements and QFEs section, select the KB940467 QFE. • I/O may not resume to SUSE and Red Hat Linux hosts upon cable reinsertion. The likelihood of this issue occurring increases with the number of LUNs configured on the storage array and load. The failover/failback process is working correctly at the multipath driver level. At the multipath application level, multipath maps are not getting updated.
Disable NTP on both controllers, set the IP address of the intended NTP server, and re-enable NTP. • When a controller is powered off or in a failed state, the Link LED remains ON although the host indicates a link down state. Disregard the Link LED when the controller removal LED is illuminated. • On the Storage Management Unit (SMU) Manage > Scheduler page, the Snapshot Prefix field allows up to 31 characters to be input but then displays an error message indicating the prefix can have 1-14 characters.