HP StorageWorks B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 10.3.4 Release Notes (5697-0436, April 2010 - includes all 10.3.x versions)

SolutionClosed defect summary
Fixed in DCFM 10.3.0
An event count of Zero is incorrectly displayed in the count column
for User Action and Authentication events generated in the Master log.
Fixed in DCFM 10.3.0
In the Alias dialog, clicking OK and Apply do nothing and the Aliases
configuration is not saved.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Use services.smc to start DCFM ser-
vices.
If you change the starting port in the Option dialog in DCFM Profes-
sional, you will not be able to start the Server Management Console
(SMC) services.
Fixed in DCFM 10.3.0
Disabling virtual fabrics returns an Enable virtual fabrics
failed error message.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Reinsert the blade, remove the ports
from the logical switch, and then re-
move the blade.
You cannot disable virtual fabrics or delete ports assigned to a logical
switch that was removed. The ports on the removed blade remain as-
signed to a logical switch.
Fixed in DCFM 10.3.0
ISL Offline event policy type action is not triggered when an ISL goes
down.
Fixed in DCFM 10.3.0
The DCFM client stopped responding, and a user received an error
message while trying to log in.
Fixed in DCFM 10.3.0
Help text for Importing a Zone does not state that the selected database
must be offline prior to the import.
Fixed in DCFM 10.3.0
DCFM does not provide activation of lossless DLS. It is only supported
with CLI or WebTools.
Fixed in DCFM 10.3.0
You cannot discover a logical switch without deleting all fabrics con-
taining that IP address.
Fixed in DCFM 10.3.0
The FICON Troubleshooting wizard is missing switches, and an error
message box is blank.
Fixed in DCFM 10.3.0
ISLs disappear from the display after fabrics are discovered and when
a monitor or unmonitor operation is performed.
Fixed in DCFM 10.3.0
With PDCM, the confirmation message while activating should include
the matrix name.
Fixed in DCFM 10.3.0
In the Topology, the Core switch is missing and only the Virtual switch
is shown.
Fixed in DCFM 10.3.0
The NPIV device type information in the CLI does not match the DCFM
product list or Encryption Add Target dialog information. NPIV targets
are not displayed in the Encryption Target dialog.
Fixed in DCFM 10.3.0
Changing the port label for a zone in the zone list does not persist
after reopening the Zoning dialog.
Fixed in DCFM 10.3.0
If a switch is set to authenticate against an LDAP or RADIUS server,
the switch loses manageability after 15 minutes and returns an author-
ization failure message.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 37