HP StorageWorks B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 10.3.4 Release Notes (5697-0436, April 2010 - includes all 10.3.x versions)

SolutionClosed defect summary
Fixed in DCFM 10.3.0
Attempting to save a zone configuration in a large fabric fails and the
following error is returned:Failed to save zone config...zon-
ing aborted...Bad zone config
Fixed in DCFM 10.3.0
An encryption event displays an unclear message: Wrong device
type: should be tape, found disk. This occurs when one
EE has a tape container and the other EE has a disk container, and
you attempt to use the Replace EE dialog, Replace function between
the two.
Fixed in DCFM 10.3.0
When resolving the FICON merge conflict for long-distance mode,
DCFM displays the failed to change message, even though the
change occurred.
Fixed in DCFM 10.3.0
You cannot move GbE ports to logical switches. An attempt returns an
inaccurate message.
Fixed in DCFM 10.3.0
When moving an entire slot port list to a logical switch, the following
obscure product event message is generated: Attempted to move
ports various on slot -1 to switch succeeded.
Fixed in DCFM 10.3.0
When enabling Virtual Fabrics on a switch that was previously dis-
covered using SNMPv1, users should receive a message instructing
them to use SNMPv3.
Fixed in DCFM 10.3.0
Immediately after enabling Virtual Fabrics, only the IP address is dis-
played. FID -1 should be displayed as well.
Fixed in DCFM 10.3.0
After canceling the Configuration wizard and restarting, the command
window appears in the background instead of the foreground.
Fixed in DCFM 10.3.0The Cascaded FICON Merge Wizard Help page does not open.
Fixed in DCFM 10.3.0
If EFCM roles or group names exceed 128 characters, migrating to
DCFM fails.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Use the CLI to add port number 767.
The Add Zone Member dialog lists the option to add ports 0766 in-
stead of 0767 for the full 768 ports when two HP StorageWorks DC
SAN Directors are connected.
Fixed in DCFM 10.3.0
The chassis group Serial number, Status, and State are not updated
in the DCFM product list. This information is available through the CLI,
and should be displayed in DCFM.
Fixed in DCFM 10.3.0
No event is generated when an HP StorageWorks 2/140 M-EOS
Director is upgraded to firmware V9.9.2. DCFM continues to use HP
StorageWorks Edge Switch 2/24 as a seed switch. The user is not
prompted to use a seed switch-capable switch.
Fixed in DCFM 10.3.0The DCFM server is not responding to the client.
Fixed in DCFM 10.3.0
Launching Port Admin from DCFM unnecessarily requests login creden-
tials.
Fixed in DCFM 10.3.0
No error message is displayed when a report generation fails due to
a disk read/write protection error.