Brocade Fabric OS v6.4.3f Release Notes v1.0
Close with Code Change in Fabric OS v6.4.2b
Fabric OS v6.4.3f Release Notes v1.0 Page 78 of 149
Defect ID: DEFECT000359160
Technical Severity: Medium
Summary: Not able to enable NPIV on FCoE ports.
Symptom: If NPIV had been disabled on FCoE ports prior to upgrading to v7.0, NPIV cannot be
enabled on those FCoE ports.
Feature: Field Escalation
Function: FCoE
Probability: Low
Found in Release: FOS7.0.0
Service Request ID: 639985
Where Else Fixed: FOS7.0.0 b PATCH
Defect ID: DEFECT000359729
Technical Severity: Medium
Summary: The Brocade 8000 running v6.4.2 does not display LLDP neighbor Port Description when
interoperating with another vendor's switch
Symptom: LLDP does not display neighbor Port Description
Feature: CEE-LAYER2
Function: LLDP
Probability: Medium
Found in Release: FOS6.4.2
Service Request ID: 642141
Defect ID: DEFECT000360537
Technical Severity: Medium
Summary: Certain traffic configuration cause back end CRC errors on FC8-64 blades in slots 3 and 9
of a DCX
Symptom: CRC errors with good EOF are reported when FC8-64 blades are installed in slots 3 or 9 of a
DCX. A reinitialization (reseat/power cycle) of blade is needed for the change to be
effective.
Feature: 16G Platform Services
Function: Other
Probability: Low
Found in Release: FOS7.0.0
Where Else Fixed: FOS7.0.0 b PATCH
Defect ID: DEFECT000363608
Technical Severity: Medium
Summary: Parity error detected on FCOE switch during supportsave collection
Symptom: Switch might fault during supportsave when non-significant parity errors were detected.
This only impacts FCOE switches
Feature: Field Escalation
Function: ASIC Driver
Probability: Low
Found in Release: FOS6.3.2