Brocade Fabric OS v6.4.3f Release Notes v1.0
Close with Code Change in Fabric OS v6.4.2b
Fabric OS v6.4.3f Release Notes v1.0 Page 76 of 149
Defect ID: DEFECT000347751
Technical Severity: Medium
Summary: Support for SFTP on FOS platforms
Symptom: Enhancement to support SFTP
Feature: Infrastructure
Function: Other
Probability: Low
Found in Release: FOS6.4.0
Defect ID: DEFECT000348516
Technical Severity: Medium
Summary: Switch failed to go active after initialization
Symptom: 4G Switch/blade may fail chip initialization. This is observed more often with BR5100
under higher temperature with portloopback test.
Feature: Field Escalation
Function: ASIC Driver
Probability: Low
Found in Release: FOS6.4.1
Service Request ID: 590691
Defect ID: DEFECT000354137
Technical Severity: Medium
Summary: User cannot config TE interface after ceeportloopbacktest
Symptom: Cannot config TE interface after running ceeportloopbacktest
Following message is displayed: "% Error: Invalid input detected at '^' marker."
Feature: Man Pages
Function: Edit/Correct
Probability: High
Found in Release: FOS6.4.2
Service Request ID: 629643
Where Else Fixed: FOS7.0.0 b PATCH
Defect ID: DEFECT000354157
Technical Severity: Medium
Summary: Brocade FCOE LACP PDU length is non-standard
Symptom: Nonstandard size LACP PDUs being discarded at the remote end and Brocade switch could
not form a dynamic LAG with a 3rd party switch.
Feature: CEE-LAYER2
Function: LACP
Probability: Low
Found in Release: FOS6.3.1_dcb
Defect ID: DEFECT000354750
Technical Severity: Medium
Summary: Unable to access the boot prom on an BR5480 when it is installed in an embedded server
chassis
Symptom: Unable to access the boot prom on a Brocade 5480.
Feature: Field Escalation
Function: EMBEDDED DRIVER
Probability: Low
Found in Release: FOS6.3.1
Service Request ID: 589577
Where Else Fixed: FOS7.0.0 b PATCH