Defect ID: DEFECT000299528
Technical Severity: Medium
Summary: When running tape operations using tape pipelining in a Brocade 7800 or FX8-24 blade,
the FCP_CONF command may be dropped, causing the tape operation to fail.
Symptom: I Series I/O stops with tape pipelining enabled, causing tape operations running over a
Brocade 7800 or FX8-24 blade to not complete successfully.
Feature: FCIP
Function: Emulation
Probability: Low
Found in Release: FOS6.3.1
Where Else Fixed: FOS6.3.2, FOS6.4.1
Defect ID: DEFECT000300954
Technical Severity: Medium
Summary: ceeturboramtest not running as part of systemverification in FCOE10-24 and Brocade
8000.
Symptom: RAM errors are not detected by systemverification diagnostic.
Feature: Diagnostics
Function: Post Diags
Probability: Low
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.4.1
Defect ID: DEFECT000301650
Technical Severity: Medium
Summary: Spinfab fails on an Eport residing in a Base switch.
Symptom: Frame drops and undefined behavior can be expected while running spinfab.
Feature: Diagnostics
Function: Other
Probability: High
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.4.1
Defect ID: DEFECT000301959
Technical Severity: Medium
Summary: In a Brocade 48000 with an FC4- 48 blade, after port enable/disable of primary port, NPIV
PIDs disappear from cam table entries, disrupting data.
Symptom: In a Brocade 48000 with an FC4- 48 blade, booting a host connected to a primary port
causes NPIV data on secondary port IO to abort.
Feature: Field Escalation
Function: ASIC Driver
Probability: High
Found in Release: FOS6.3.0
Service Request ID: 422909