Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.1
Fabric OS v6.4.3f Release Notes v1.0 Page 120 of 149
Defect ID: DEFECT000288870
Technical Severity: High
Summary: Converged Network Adapter (CNA) cannot login during shut/no shut operation
Symptom: CNA is not able to log in to Brocade 8000 / FCOE10-24 blade.
Feature: CEE-FCOE
Function: FCOE DRIVER
Probability: Low
Found in Release: FOS6.3.1_cee
Where Else Fixed: FOS6.3.2, FOS6.4.1
Defect ID: DEFECT000289212
Technical Severity: High
Summary: During long-running stress test that involves repeated ISL and I/O synch link disabling,
rekey for a LUN appeared stuck
Symptom: Rekey gets stuck
Feature: Data Security
Function: Re-key
Probability: Low
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.4.1
Defect ID: DEFECT000289315
Technical Severity: High
Summary: Storage ports can get stuck as an N_Port with status "Disabled (Fabric Login Failed)" in AG
mode with Auto Policy enabled
Symptom: Some devices are unable to login because the port on AG is locked as N_Port. There is no
CLI to "unlock" the port configuration, so the devices are never able to login.
Workaround: Re-boot AG switch
Feature: Access Gateway Services
Function: Platform Other
Probability: Medium
Found in Release: FOS6.2.2
Where Else Fixed: FOS6.4.1
Defect ID: DEFECT000289847
Technical Severity: High
Summary: FC4-16IP "iscsicfg --commit all" hangs switch telnet session.
Symptom: When trying to commit any iSCSI configuration, the operation will not finish, telnet session
will hang. A hafailover is needed to recover from this. This only applies to FC4-16IP blades.
Feature: Field Escalation
Function: ISCSI
Probability: High
Found in Release: FOS6.3.0
Service Request ID: 420861
Where Else Fixed: FOS6.3.2, FOS6.4.1