Brocade Fabric OS v6.4.3f Release Notes v1.0
Close with Code Change in Fabric OS v6.4.1a
Fabric OS v6.4.3f Release Notes v1.0 Page 111 of 149
Defect ID: DEFECT000301856
Technical Severity: Medium
Summary: Boot Over SAN fails with switch port set to 8GB on Brocade 5470.
Symptom: A 3rd party device connected to a Brocade 5470 takes a long time to come online and boot
over SAN can fail.
Feature: Embedded Platform Services
Function: BR 5470 Integration
Probability: Low
Found in Release: FOS6.3.1
Where Else Fixed: FOS6.3.2 b, FOS6.4.1 a
Defect ID: DEFECT000305690
Technical Severity: Medium
Summary: Access Gateway trace data does not contain complete enough information for path loss
debugging. AG tracing needs to be improved to allow path loss traces to be gathered
properly.
Symptom: None, other than that the AG trace data does not contain complete debugging information.
Feature: Field Escalation
Function: Access Gateway
Probability: High
Found in Release: FOS6.2.2
Service Request ID: 429507
Where Else Fixed: FOS6.2.2 d, FOS6.4.1 a
Defect ID: DEFECT000308933
Technical Severity: Medium
Summary: Additional port counters/statistics available in SW MIB need to be exposed via SNMP.
Symptom: SW MIB counters such as Link Error State Block, Port Level Performance/Error, and other
similar objects are available through CLI but not through SNMP.
Feature: Mgmt Embedded - SNMP
Function: Other
Probability: Low
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.2.2 d, FOS6.3.2 b, FOS6.4.1 a
Defect ID: DEFECT000311542
Technical Severity: Medium
Summary: User cannot create Certificate Signing Request (CSR) files with seccertutil command
Symptom: On a switch with only IPv6 Address configured, creating Certificate Signing Request (CSR)
fails.
Workaround: Add an IPv4 address to switch configuration.
Feature: Field Escalation
Function: Security
Probability: Low
Found in Release: FOS6.2.2
Service Request ID: 445003