Brocade Fabric OS v6.4.3f Release Notes v1.0 March 21, 2014 Document History Document Title Summary of Changes Publication Date Brocade Fabric OS v6.4.3f Release Notes v1.
© 2014 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, MLX, SAN Health, VCS, and VDX are registered trademarks, and AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners.
Contents Quick Look ................................................................................................................................................... 5 Overview ...................................................................................................................................................... 5 Resolution of Important Defects ................................................................................................................................
Traffic Isolation over FCR....................................................................................................................................... 29 Integrated Routing ................................................................................................................................................... 29 Native Connectivity ................................................................................................................................................. 30 FCAP ...
Quick Look Fabric OS (FOS) v6.4.3f is a patch release based on FOS v6.4.3. All hardware platforms and features supported in FOS v6.4.3 are also supported in FOS v6.4.3f. In addition to the fixes listed in the defect tables at the end of this document, FOS v6.4.3f also includes support for the features introduced in FOS v6.4.3. Overview Resolution of Important Defects FOS v6.4.
Brocade Extended Fabrics — Provides greater than 10km of switched fabric connectivity at full bandwidth over long distances (depending on platform this can be up to 3000km). Brocade ISL Trunking — Provides the ability to aggregate multiple physical links into one logical link for enhanced network performance and fault tolerance. Also includes Access Gateway ISL Trunking on those products that support Access Gateway deployment.
to enable full encryption processing power on the BES or on all FS8-18 blades installed in the DCX/DCX-4S chassis. DataFort Compatibility — This license is required on the Brocade Encryption Switch/DCX/DCX-4S with FS8-18 blade(s) to read & decrypt NetApp DataFort-encrypted disk and tape LUNs.
Fabric (E_Port) license Extended Fabric license Trunking license High Performance Extension license Advanced Performance Monitoring license Adaptive Networking license Fabric Watch license Integrated Routing license Server Application Optimization license Advanced Extension license Advanced FICON Acceleration license 10GbE FCIP license Note: Temporary Licenses for features available on a per slot basis enable the feature for any and all slots in the chassis.
deployment in M-EOS fabrics with the exception of the Brocade 4100 and 8000 and DCX/DCX-4S with one or more FCOE10-24 blades. Access Gateway mode is also supported by Fabric OS v6.4.3, and is supported on the following switches: the Brocade 300, 5100, VA-40FC, 8000, 5450, 5460, 5470, 5480, NC-5480 and M5424. Note: Although Fabric OS v6.4.
Standards Compliance This software conforms to the Fibre Channel Standards in a manner consistent with accepted engineering practices and procedures. In certain cases, Brocade might add proprietary supplemental functions to those specified in the standards. For a list of FC standards conformance, visit the following Brocade Web site: http://www.brocade.com/sanstandards The Brocade 8000 and FCOE10-24 blade conform to the following Ethernet standards: IEEE 802.1D IEEE 802.1s IEEE 802.
The serial number label is located as follows: Brocade 4100, 4900, and 7500/7500E — On the switch ID pull-out tab located inside the chassis on the port side on the left Brocade Encryption Switch, VA-40FC, 300, 5000, 5100, and 5300 — On the switch ID pull-out tab located on the bottom of the port side of the switch Brocade 7600 — On the bottom of the chassis Brocade 7800 — On the pull-out tab on the front left side of the chassis underneath the serial console and Ethernet connection and on th
FOS Migration Considerations This section contains important details to consider before migrating to or from this FOS release. TSBs - Critical Issues to Consider Prior to Installing This FOS Release Technical Support Bulletins (TSBs) are produced to provide detailed information about high priority defects or issues present in FOS releases. The following sections specify all current TSBs that have been identified as being a risk to or resolved with this specific version of Fabric OS.
TSB Summary TSB 2011-108-A Upon upgrading a Fabric switch to v6.4.1. or 6.4.1a, F_Port trunking used to connect any Access Gateways will not be allowed if the Fabric switch does not have a SAO (Server Application Optimization) license installed. This will eventually result in connectivity loss between the AG and switch if attached via F_Port trunks.
If Bottleneck detection feature is currently enabled on the switch running FOS v6.3.x, you must disable it before upgrading to FOS v6.4; otherwise, frame drops may occur due to increased Hot Code Load (HCL) time. 7800 platform and FX8-24 blade must be power cycled after upgrading from FOS v6.3 to FOS v6.4. This is necessary to load the new FPGA image that enables IPv6 capability for FCIP links to 7800 and FX8-24 blade. This step is mandatory even if IPv6 will not be used on the FCIP ports.
supported on version 12.1.5 or later. With JRE 1.7.0 update 51, users could see some browser warning messages that can be ignored. WebTools is supported with Google Chrome browser with FOS v6.4.3f. When launching WebTools on a computer without Internet access, it could take upto 5 minutes to complete because the certicate revocation check performed for the WebTools application takes time to timeout. Users can turn off the certification revocation check on the Java control panel as a workaround.
Supported Products and FOS Interoperability Brocade 7800, DCX and DCX-4S with FCOE10-24 or FX8-24 blades v6.3 and later Brocade DCX and DCX-4S with FC8-64 blade v6.4 Brocade DCX, 300, 5100, 5300 v6.1.0e and later 5 VA-40FC v6.2.1_vfc, v6.2.2, v6.3.1, v6.4 Brocade DCX-4S v6.2.0 and later Brocade DCX with FS8-18 blade(s), Brocade Encryption Switch v6.1.1_enc and later Brocade DCX/DCX-4S/48000 with FA4-18 blade(s), Brocade 7600 v5.2.x or later (DCX requires v6.0.x or later, DCX-4S requires 6.2.
Fabric OS v6.4 software is fully qualified and supports the blades for the 48000 platform noted in the following table: 48000 Blade Support Matrix Port blade 16, 32 and 48-port 4Gbit blades (FC4-16, FC4-32, FC4-48), 16, 32 and 48-port 8Gbit blade (FC8-16, FC8-32, FC8-48), and the 6-port 10G FC blade (FC10-6) Supported with any mix and up to 8 of each. No restrictions around intermix. The 48000 must run Fabric OS v6.0 or later to support the FC8-16 port blade and Fabric OS v6.
DCX/DCX-4S Blade Support Matrix FCoE/CEE Blade (FCOE10-24) Up to a maximum of 2 blades of this type. Cannot be used in a chassis with other intelligent blades (can only be installed concurrently with FC8-XX and/or FC10-6 blades). Cannot be used in a DCX/DCX-4S chassis with FC8-64 blade in FOS v6.4. Note: the iSCSI FC4-16IP blade is not qualified for the DCX/DCX-4S. Fabric OS v6.4.3f Release Notes v1.
Power Supply Requirements for Blades in 48k and DCX/DCX-4S Chassis Blades Type of Blade 48K @200-240 VAC (Redundant configurations) DCX/DCX-4S @110 VAC (Redundant configurations) DCX/DCX-4S @200-240 VAC (Redundant configurations) FC4-16, FC 4- Port Blade 32, FC4-48, FC8-16, FC832 2 Power Supplies 2 Power Supplies 2 Power Supplies FC10-6, FC816, FC8-32, FC 8-48, FC8-641 Port Blade 4 Power Supplies Not Supported 2 Power Supplies FR4-18i, FC4-16IP2, FA4-18 Intelligent Blade 4 Power Supplies No
FOS Feature Compatibility in Native Connectivity Modes Some FOS features are not fully supported when operating in the native connectivity modes for deployment with M-EOS based products. All Brocade models that are supported by Fabric OS v6.4 support both interopmodes 2 and 3 with the exception of the Brocade 4100 and 8000 and DCX/DCX-4S with one or more FCOE10-24 blades.
FOS Features (supported in interopmode 0) IM = Interopmode FCIP (VE_Ports) IPFC (IP over FC) M-EOS ALPA 0x13 configuration VE to VEX Port Integrated Routing9 Domain Offset Support 239 Domain Support (available on Mi10k only) Masterless F_PORT Trunking (AG connect to FOS switches only) FC10-6-to-FC10-6 ISL RASLOG Events on duplicate WWNs Virtual Fabrics Logical Fabric using LISLs (XISLs in Base Fabric) Port Fencing Bottleneck Detection Lossless DLS FOS v6.
Other Important Notes and Recommendations Management Server Platform Capability support changes in FOS v6.4 FOS v6.4 no longer automatically enables the Management Server (MS) Platform capability when a switch attempts to join a fabric that has these services enabled. This prevents a FOS v6.4 switch from joining such a fabric, and ISL will be disabled with a RAS log message. To allow a FOS v6.
Differences between the Brocade 7800/FX8-24 platforms and previous generation 7500/FR4-18i platforms include: o On the 7800, the GbE port does not directly correlate to a VE port o On the FX8-24, GbE ports 0-9 or 10GbE port 1 (xge1) correspond to VE ports 12-21, and 10 GbE port 0 (xge0) corresponds to VE ports 22-31 o The CLI syntax for the 7800/FX8-24 varies from the 7500/FR4-18i. Please refer to the Brocade Fabric OS Command Reference document for FOS v6.
When operating in Converged Mode, tagged traffic on the native VLAN of the switch interface is processed normally. The host should be configured not to send VLAN tagged traffic on the switch’s native VLAN. When operating in Converged Mode, tagged frames coming with a VLAN tag equal to the configured native VLAN are dropped. The Converged Network Adapter (CNA) may lose connectivity to the Brocade 8000/FCOE10-24 if the CNA interface is toggled repeatedly over time.
An FCOE10-24 blade installed in the highest numbered slot of a DCX or DCX-4S chassis does not send out FIP unsolicited advertisements. Therefore, it does not support FCoE functionality when installed in this slot. The Brocade 8000 and FCOE10-24 can handle 169 small FCoE frames in bursts. If you are using the Brocade 8000 or FCOE10-24, and you delete a large number of v-ports with HCM, some of the v-ports may not appear to be deleted.
o Maximum of 6 Encryption nodes per Windows/Linux TKLM server. o Maximum of 10 Encryption nodes per AIX TKLM server. o Maximum of 16 tape sessions per Encryption node. o Minimum of 180 second timeout for tape hosts. Disk Encryption Rekey: Configupload/download does not retain the auto rekey value. The first auto rekey after configdownload will occur based on the previously configured key life. The newly configured key life value (as part of configdownload) will be used after the first auto rekey.
For dual LKM configuration on the Brocade Encryption Switch (BES) or a DCX/DCX-4S with FS8-18 blades as the primary and secondary key vaults, these LKM appliances must be clustered (linked). Failure to cluster will result in key creation failure. Otherwise, register only one LKM on the BES/FS818 Encryption Group. Please refer to the Encryption Admin Guide for configuration information. The RKM Appliance A1.6, SW v2.7 is supported.
When disk and tape CTCs are hosted on the same encryption engine, re-keying cannot be done while tape backup or restore operations are running. Re-keying operations must be scheduled at a time that does not conflict with normal tape I/O operations. The LUNs should not be configured with auto rekey option when single EE has disk and tape CTCs.
Users who want to utilize Access Gateway’s Device-based mapping feature in the ESX environments are encouraged to refer to the SAN TechNote GA-TN-276-00 for best implementation practices. Please follow these instructions to access this technote: o Log in to http://my.brocade.com o Go to Documentation > Tech Notes. o Look for the Tech Note on Access Gateway Device-Based Mapping in VMware ESX Server.
Integrated Routing and TopTalkers (Fabric Mode) are not concurrently supported. To use Integrated Routing, be sure to disable Fabric Mode TopTalkers prior to configuring EX_Ports first. Native Connectivity FOS-based platforms operating in interopmodes 2 or 3 should never be deployed in a fabric without at least one M-series switch. FOS switches in interopmode 3 (McDATA Open Fabric Mode) do not support configuration of zoning without an M-series switch in the fabric.
10G Interoperability 10G interop between FC10-6 and McDATA blades is not supported due to a HW limitation, however the FC10-6 is supported in a chassis running in Interopmode 2 or 3 (FC10-6 to FC10-6 connections only). An FC10-6 blade will not synchronize with a McDATA 10G blade. However, the inability to synchronize will not negatively impact the system. Port Fencing The state changes counter used by Fabric Watch in FOS v6.
flow control mode that uses IDLE primitives does not support Brocade frame-based Trunking for devices such as Time Division Multiplexor (TDM.) In order to overcome this limitation and provide support for frame-based Trunking with Extended Fabrics, Fabric OS v6.2.0 and later has been enhanced to support interoperability with these distance extension devices. Fabric OS v6.3.1 allows Extended Fabrics E_Ports to operate in VC_RDY mode using either ARB or IDLE primitives as fill words.
The portCfgFillWord command, applicable to 8G-capable ports, has been enhanced with FOS v6.3.1 and v6.4 to provide two new configuration options (Modes 2 and 3). The available settings include: Mode Link Init/Fill Word Mode 0 – IDLE/IDLE Mode 1 – ARBF/ARBF Mode 2 – IDLE/ARBF Mode 3 – If ARBF/ARBF fails use IDLE/ARBF Although this setting only affects devices logged in at 8G, changing the mode is disruptive regardless of the speed the port is operating at.
Enables serdes tuning mode and sets new serdes values on FC8-16 blades in slot 2 and 7 and on peer ports in the CR4S-8 blade. – reset Clears serdes tuning mode and resets the old serdes values on the FC8-16 blades in slot 2 and 7 and on peer ports in CR4S-8 blade. – show Displays whether the serdes tuning mode is enabled or disabled. – help Displays the serdestunemode command usage.
Defects Closed with Code Change in Fabric OS v6.4.3f This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of March 21, 2014 in Fabric OS v6.4.3f. Defect ID: DEFECT000333591 Technical Severity: Low Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.0.0 Technology Area: SNMPv2, SNMPv3 & MIBs Closed In Release(s): FOS6.4.3f(Fixed) Symptom: FOS doesn't have any command to disable snmpv1.. Condition: FOS v6.4.
Closed with Code Change in Fabric OS v6.4.3f Defect ID: DEFECT000418392 Technical Severity: High Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.1.0 Technology Area: Web Tools Closed In Release(s): FOS6.4.3f(Fixed) Symptom: Weblinker crash while the fabric is being monitored by BNA Condition: This may be encountered in a large fabric with security policy activated.
Closed with Code Change in Fabric OS v6.4.3f Defect ID: DEFECT000461189 Technical Severity: High Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: Web Tools Closed In Release(s): FOS6.4.3f(Fixed) Symptom: Unable to launch WebTools using Google Chrome browser and IE11 with Java update 45 or 51 Condition: This happens when using the latest Java update revision 45 or 51. Workaround: Use another browser or older Java update.
Closed with Code Change in Fabric OS v6.4.3f Defect ID: DEFECT000479046 Technical Severity: Critical Probability: Low Product: FOS Technology: FICON Reported In Release: FOS6.4.3 Technology Area: FICON emulation Closed In Release(s): FOS6.4.3f(Fixed) Symptom: Customer observed frequent suspends in XRC emulation environment. Condition: When there is immediate command retry, XRC Emulation may not correctly handle Immediate Retry Status.
Closed with Code Change in Fabric OS v6.4.3f Defect ID: DEFECT000487235 Technical Severity: High Probability: High Product: FOS Technology: Virtualization Reported In Release: FOS7.1.1 Technology Area: Access Gateway Closed In Release(s): FOS6.4.3f(Fixed) Symptom: Hosts are not able to login to the Access Gateway after the Access Gateway is rebooted. Condition: The problem occurs under these conditions: - No Access Gateway policies are enabled -- i.e.
Closed with Code Change in Fabric OS v6.4.3e This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of June 25, 2013 in Fabric OS v6.4.3e. Defect ID: DEFECT000319259 Technical Severity: High Summary: BR8000 experienced cald memory errors when assigning an ACL to a LAG Symptom: Switch experienced panic when managed under BNA Probability: High Feature: CEE-MANAGEABILITY Function: CAL INTERFACE Reported In Release: FOS6.4.
Closed with Code Change in Fabric OS v6.4.3e Defect ID: DEFECT000414944 Technical Severity: Medium Summary: CRC errors on port with LWL SFP running at 8Gbit/sec Symptom: Diagnostics fail and CRC errors are observed on an 8Gbit/sec link with a specific LWL optics. Probability: High Feature: FOS Software Reported In Release: FOS7.0.
Closed with Code Change in Fabric OS v6.4.3e Defect ID: DEFECT000429815 Technical Severity: High Summary: BR5480 exhibits snmpd crash and switch reboot when being managed by BNA. Symptom: BR5480 switches running in AG mode and managed by BNA exhibit snmpd crash and switch reboot. Workaround: Avoid managing an AG switch with BNA or have all ports connected to either N_Port or F_port or have AG in auto policy disabled state.
Closed with Code Change in Fabric OS v6.4.3e Defect ID: DEFECT000442422 Technical Severity: High Summary: System security card is not being read on BES/FS8-18 card readers. Symptom: Authentication for crypto operations on BES/FS8-18 fails. In this case, BES/FS8-18 functions as an ordinary FC switch or blade when it is powered up, but use of the encryption engine is denied as a result. Workaround: Disable the systemcard feature, issue cryptocfg -- set -systemcard disable from the encryption group leader.
Closed with Code Change in Fabric OS v6.4.3e Defect ID: DEFECT000451617 Technical Severity: Medium Summary: Unstable link caused switch to internally reset port and generated link level errors. Symptom: On embedded switch, after upgrading FOS, observed high count of LOSSYNC, link failure errors during server boot.There is no impact to the time for port to come online, but the counters triggered fabric watch warnings. Feature: 4G ASIC Driver Function: PORT Reported In Release: FOS6.3.
Closed with Code Change in Fabric OS v6.4.3d This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of March 20, 2013 in Fabric OS v6.4.3d. Defect ID: DEFECT000422477 Technical Severity: High Summary: HBA on embedded switch port does not login correctly after the host is rebooted or unstable ICL/other ports can cause switch reboot Symptom: Embedded switch port must be disabled/enabled once the host is fully booted to support successful HBA login.
Closed with Code Change in Fabric OS v6.4.3c This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of September, 2012 in Fabric OS v6.4.3c. Defect ID: DEFECT000357943 Technical Severity: High Summary: Trackchanges is not generating TRK-1003 for SSH logout. Symptom: With a Trackchanges setting of 1,1, the track changes feature is not generating the TRCK-1003 message when a SSH session is logged out.
Closed with Code Change in Fabric OS v6.4.3c Defect ID: DEFECT000412938 Technical Severity: Medium Summary: Fabric Watch erroneously reporting a "build fabric" Symptom: On a busy switch, Fabric Watch falsely reports "build fabric" event. Probability: Low Feature: FOS Software Function: System Performance Reported In Release: FOS6.4.1 Service Request ID: 756411 Defect ID: DEFECT000413879 Technical Severity: Medium Summary: Unreachable switches are seen as Brocade 200E in Brocade Network Advisor dashboard.
Closed with Code Change in Fabric OS v6.4.3c Defect ID: DEFECT000415731 Technical Severity: High Summary: Detected termination of process cnmd panic when executing security scans against directors Symptom: Switch panics when being aggressively scanned by security software Probability: High Feature: Data Security Function: Encryption Group FOS7.1.
Closed with Code Change in Fabric OS v6.4.3b This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of September, 2012 in Fabric OS v6.4.3b. Note: Fabric OS 6.4.3b supersedes v6.4.3a which was not released and is not available. DEFECT000405323 Technical Severity: High AG parsing loop caused low memory leading to switch panic Switch panics and this issue only exists in FOS 6.4.
Close with Code Change in Fabric OS v6.4.3b Defect ID: DEFECT000383577 Technical Severity: High Summary: CRC with good EOF detected on ICL ports Symptom: Observed CRC with good EOF on multiple ICL ports between a DCX and DCX-4S. Probability: Low Feature: FOS Software Function: ASIC Driver Reported In Release: FOS6.4.2 Service Request ID: 693593,693593 Defect ID: DEFECT000387013 Technical Severity: Medium Summary: Stale AG entry remains present in management server database after the removal of AG.
Close with Code Change in Fabric OS v6.4.3b Defect ID: DEFECT000394917 Technical Severity: Medium Summary: Slow CLI response time running FOS v7.x Symptom: User may notice the slowness when run a script with many commands; individual command response time is still within second. Probability: Medium Feature: FOS Software Function: OS: Linux Reported In Release: FOS7.0.
Close with Code Change in Fabric OS v6.4.3b Defect ID: DEFECT000400194 Technical Severity: High Summary: Selected switch configuration accessible without authenticating Symptom: Able to query switch via HTTP for information without authenticating with a username/password Probability: High Feature: FOS Software Function: Security Reported In Release: FOS6.0.
Close with Code Change in Fabric OS v6.4.3b Defect ID: DEFECT000405501 Technical Severity: Medium Summary: Brocade 5460 POST timeout, takes over 60 secs to complete Symptom: Third party management module timeout and reset. Probability: Low Feature: Embedded Platform Services Function: Other Reported In Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.3b Defect ID: DEFECT000410424 Technical Severity: Medium Summary: Turn off serdes transmitter for unlicensed ports on Brocade 300 and 5300 Symptom: Hardware tool shows serdes is still on and generate signals on ports without POD license cause EMI issue. Workaround: Run portdisable CLI on ports without POD license Probability: Low Feature: 8G ASIC Driver Function: C2 ASIC driver Reported In Release: FOS6.4.
Closed with Code Change in Fabric OS v6.4.3 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of April 18, 2012 in Fabric OS v6.4.3. Defect ID: DEFECT000405323 Technical Severity: High Summary: AG parsing loop caused low memory leading to switch panic Symptom: Switch panics and this issue only exists in FOS 6.4.3 GA code Probability: Medium Feature: OS Services Function: Linux Kernel Reported In Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000339004 Technical Severity: High Summary: Keeping nameserver and zoneadmin open through WebTools with 2MB cfg in 20mins, session became unusable Symptom: WebTools becomes unusable and session expires Workaround: CLI Feature: WebMgmt Function: Name Server Probability: Medium Found in Release: FOS7.0.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000352764 Technical Severity: High Summary: Remote data replication application fails with multiple paths (multiple port pairs between arrays) when FastWrite is enabled on the FCIP tunnel. Symptom: With FastWrite enabled on an FCIP tunnel, and two data replication port pairs, the application commands to move data between the arrays will fail. With only a single port pair or with FastWrite disabled, everything works fine.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000358972 Technical Severity: High Summary: Port is negotiating to 16G even though optic is only capable of 8G Symptom: Customer will see multiple problems with I/O. Workaround: bounce the problem port with this kind of mismatch speed setting. Feature: 16G Platform Services Function: FOS Kernel HA Probability: Medium Found in Release: FOS7.0.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000369703 Technical Severity: High Summary: Host could not Link up on 8G FC port when the port is configured at a fixed speed of 4G or 8G. Symptom: After switch reboot, or slotpoweroff/slotpoweron, a port may sometimes not gain sync and also fail to recover using portdisable/portenable.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000375295 Technical Severity: High Summary: F_Port stuck in Disabled (N-Port Offline for F-Port) after AG reboot Symptom: F_Ports on some access gateways are stuck in F_Port Disabled state (N-Port Offline for FPort) and observe raslog reports: [AG-1005], FDISC response was dropped. Feature: Field Escalation Function: Access Gateway Probability: Low Found in Release: FOS6.2.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000383769 Technical Severity: High Summary: Switch clears all pending exchange upon receive busy status with "abort task set" causing missing blocks on tape. Symptom: Missing blocks on tapes written when tape pipelining is enabled. Feature: FCIP Function: Emulation Probability: Low Found in Release: FOS6.4.1_fcoe Service Request ID: 682259 Defect ID: DEFECT000384682 Technical Severity: High Summary: Downgrade from FOS v7.0.x to v6.4.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000394458 Technical Severity: High Summary: FCIP tunnel failure and reboot due to processing exception in FICON Emulation Abort processing Symptom: Channel detected errors and loss of path, FCIP Tunnel bounce (when the complex rebooted). Workaround: Disable FICON emulation on the FCIP Tunnel Feature: FCIP Function: FCIP CP Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000337419 Technical Severity: Medium Summary: FCoE traffic wouldn't flow through when the ISL is set to Long Distance mode with VC translation=0 Symptom: FCoE traffic wouldn't flow through when Long Distance mode enabled (either, LD,LE or LS) with VC translation set to 0. Workaround: configure Long distance with vc_init flag (1) Feature: 8G ASIC Driver Function: ASIC Driver Probability: Low Found in Release: FOS7.0.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000351796 Technical Severity: Medium Summary: Duplicate E_Port SCN from Port... error messages seen after an HAFailover. Symptom: Duplicate E_Port SCN error messages being seen after an HAFailover Feature: FC Services Function: Other Probability: Low Found in Release: FOS6.4.2 Where Else Fixed: FOS7.0.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000361822 Technical Severity: Medium Summary: FastWrite is clearing the F_CTL priority bit resulting in CS_CTL values not being maintained/used Symptom: Configured CS_CTL values are no longer valid on write data frames (F_CTL priority bit disabled) once frames are carried over FCIP links with FastWrite enabled. Feature: FCIP Function: Emulation Probability: Medium Found in Release: FOS7.0.0 Where Else Fixed: FOS7.0.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000366776 Technical Severity: Medium Summary: Fabric Watch may not monitor every SNMP event Symptom: With High=0 and Low=0, Fabric watch does not monitor every SNMP event. Feature: Field Escalation Function: SNMP Probability: Low Found in Release: FOS6.3.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000368909 Technical Severity: Medium Summary: AG is not registering descriptor and creating /var/log/ag_desc.txt Symptom: Switch experiences excessive CF usage due to generation of /var/log/ag_desc.txt. Feature: Field Escalation Function: Management Services Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000373854 Technical Severity: Medium Summary: BES does not do LOCATE to the correct position after PI does a PLOGI/PRLI during restore Symptom: Tape restore job keeps waiting for data even after read is done and would eventually fail. Feature: Data Security Function: Tape Encryption Probability: Low Found in Release: FOS7.0.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000379613 Technical Severity: Medium Summary: spinFab does not work from switches running FOS v6.4.x to switches with FOS v6.2.x Symptom: spinfab reports FAIL Feature: Diagnostics Function: Other Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000381459 Technical Severity: Medium Summary: FCIP FastWrite: SRDF cannot handle busy response to commands Symptom: Customer may get data corruption on SRDF replication with FCIP FastWrite enabled. Workaround: Disable emulation Feature: Field Escalation Function: FCIP Probability: Medium Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000387287 Technical Severity: Medium Summary: OUI information changed for a specific OEM Symptom: Updated OEM specific OUI name, no functional impact Feature: OS Services Function: Other Probability: Low Found in Release: FOS6.4.0 Defect ID: DEFECT000388283 Technical Severity: Medium Summary: zoned caused switch panic Symptom: During rename zone, add new zone name in list and then remove the old zone name, switch panic.
Close with Code Change in Fabric OS v6.4.3 Defect ID: DEFECT000389661 Technical Severity: Medium Summary: WT Login : VeriSign Code Signing Certificate update for Web Tools Symptom: WT will be consider as UN-trusted application to the user. After the code fix, when launch WT first time with the updated certificate in FOS v7.0.1a, a warning dialog will be displayed. User can verify the certificate details (Issuer/Validity/Subject) by clicking “More information” in dialog.
Closed with Code Change in Fabric OS v6.4.2b – GA September 20, 2011 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of September 20, 2011 in Fabric OS v6.4.2b. Defect ID: DEFECT000326023 Technical Severity: High Summary: Switch hafailover in IPFC setup. Symptom: With IPFC configuration, run IPFC Broadcast frames with multi frames in sequence, observe switch fails over or hareboot after some run time.
Close with Code Change in Fabric OS v6.4.2b Defect ID: DEFECT000351152 Technical Severity: High Summary: Name server assert triggered switch panic Symptom: Switch reboot or hafailover observed when Admin Domain (AD) database was not in sync and there was port offline event on local/remote switch. Feature: Field Escalation Function: Fabric Services Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2b Defect ID: DEFECT000359245 Technical Severity: High Summary: The NS contains stale entries after a bad disk is removed from a loop attached device. Symptom: When a disk is removed from a loop attached device, the PID still shows up in the name server. Workaround: port bounce where the device connected. Feature: FC Services Function: Name Server Probability: Medium Found in Release: FOS6.3.2 Service Request ID: 641021 Where Else Fixed: FOS7.0.
Close with Code Change in Fabric OS v6.4.2b Defect ID: DEFECT000347751 Summary: Support for SFTP on FOS platforms Symptom: Enhancement to support SFTP Feature: Infrastructure Technical Severity: Medium Function: Other Probability: Low Found in Release: FOS6.4.0 Defect ID: DEFECT000348516 Technical Severity: Medium Summary: Switch failed to go active after initialization Symptom: 4G Switch/blade may fail chip initialization.
Close with Code Change in Fabric OS v6.4.2b Defect ID: DEFECT000356778 Technical Severity: Medium Summary: Kernel panic following insertion/removal of SFP on B8000 Symptom: Kernel panic following rapidly insertion/removal of SFP in 10Gbit port on B8000. Workaround: Please avoid reseating the SFPs in a quick succession. Feature: Field Escalation Function: Panic / OOM Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2b Defect ID: DEFECT000359160 Technical Severity: Medium Summary: Not able to enable NPIV on FCoE ports. Symptom: If NPIV had been disabled on FCoE ports prior to upgrading to v7.0, NPIV cannot be enabled on those FCoE ports. Feature: Field Escalation Function: FCoE Probability: Low Found in Release: FOS7.0.0 Service Request ID: 639985 Where Else Fixed: FOS7.0.
Close with Code Change in Fabric OS v6.4.2b Defect ID: DEFECT000364788 Technical Severity: Medium Summary: Unreliable speed negotiation may be encountered when BR5470 Cu ports are connected to a 3rd party HBA. Symptom: 3rd party HBA's are not properly negotiating to the correct speeds Feature: 8G ASIC Driver Function: PORT Probability: Medium Found in Release: FOS6.3.2 Fabric OS v6.4.3f Release Notes v1.
Closed with Code Change in Fabric OS v6.4.2a – GA July 22, 2011 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of July 22, 2011 in Fabric OS v6.4.2a.
Close with Code Change in Fabric OS v6.4.2a Defect ID: DEFECT000346417 Technical Severity: High Summary: On BES: Seeing message [CVLC-1009], 818598, FID 128, ERROR, FEN_BES_01, Wrong device type: should be tape, found disk. Symptom: BES switch is hanging/going faulty and stopping all tape backup operations Feature: Field Escalation Function: Encryption Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2a Defect ID: DEFECT000350457 Technical Severity: High Summary: Access Gateway N-port stuck in G-port after firmware upgrade with QoS enabled on attached Fabric switch Symptom: AG N_Port could be stuck in G_Port after firmware upgrade. Workaround: If this issue is encountered, disable QoS on the Fabric switch for the impacted link. Feature: Field Escalation Function: Access Gateway Probability: Low Found in Release: FOS6.3.
Close with Code Change in Fabric OS v6.4.2a Defect ID: DEFECT000328463 Technical Severity: Medium Summary: Switch View: Port status not getting updated for FAULTY blades Symptom: Port status not getting updated for FAULTY blade in switch view Feature: WebMgmt Function: Switch Explorer/Switch View Probability: Medium Found in Release: FOS7.0.
Close with Code Change in Fabric OS v6.4.2a Defect ID: DEFECT000335811 Technical Severity: Medium Summary: RFE: Brocade 5450 switches crashed when latest version of management SW was used. Symptom: Brocade 5450 platform may panic if used with newer version of MMB that uses new ISMIC block which was previously not supported. Workaround: Use initial qualified MMB version. Feature: Field Escalation Function: Panic / OOM Probability: Low Found in Release: FOS6.2.
Close with Code Change in Fabric OS v6.4.2a Defect ID: DEFECT000347807 Technical Severity: Medium Summary: New diagnostic command pterrshow to display ASIC back-end errors Symptom: For backend ports, there is no easy way to diagnostic backend link level errors. This new command will support 8G ASIC first. There is no functional impact to customer. Feature: 8G ASIC Driver Function: C2 ASIC driver Probability: Medium Found in Release: FOS6.4.2 Where Else Fixed: FOS6.3.
Close with Code Change in Fabric OS v6.4.
Close with Code Change in Fabric OS v6.4.2a Defect ID: DEFECT000352773 Technical Severity: Medium Summary: Customer is experiencing CRC errors on large data transfers using 3rd party Tape Drives on encryption products Symptom: Customers have experienced intermittent CRC errors when performing large data reads from 3rd party tape drives which may result in data read failures. Feature: FC Services Function: Other Probability: Low Found in Release: FOS6.4.
Closed with Code Change in Fabric OS v6.4.2 – GA April 7, 2011 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of April 7, 2011 in Fabric OS v6.4.2. Defect ID: DEFECT000317586 Technical Severity: Critical Summary: Fabric alias names were lost in IM2 mode.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000321051 Technical Severity: High Summary: Brocade 7800 data path processor panic occurred during tunnel bounce testing Symptom: Temporary FCIP traffic disruption will result if this issue is encountered. Feature: FCIP Function: FCIP Port Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000332542 Technical Severity: High Summary: Fault occurs during switchdisable/switchenable script testing. Symptom: It's unlikely to happen, but hafailover of a director or reboot of a switch will result if this issue is encountered. Feature: FOS-Infrastructure Function: FOS-RTE Probability: Medium Found in Release: FOS7.0.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000337355 Technical Severity: High Summary: Switches running FOS v6.4.x lose manageability from WebTools/DCFM, all LED's on switch are amber. Symptom: After upgrading switches to FOS v6.4.x, Snmpd is not running after system resource depleting. Customer may notice that all LED's on the switch are amber and/or a message from webtools/DCFM that chassis is not ready for management now, try again later.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000288974 Technical Severity: Medium Summary: After enabling https, a failover will cause the active CP to still be running http Symptom: Customer will not have https services after a failover. Workaround: Issue another hafailover to cause both CPs to reset the web services. Feature: Mgmt Embedded - HTTP Function: Other Probability: Medium Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000307484 Technical Severity: Medium Summary: Unable to initiate TPERF session Symptom: User may not be able to initiate a TPERF session under certain circumstances Feature: FCIP Function: FCIP CLI Probability: Medium Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000313440 Technical Severity: Medium Summary: Command reject, Core hang on FICON Emulation I/O in an XRC or FICON tape pipelining configuration Symptom: Multiple symptoms could be observed, such as Abort IO, IFCC, path failure, XRC suspension with Brocade 7500, 7800 or FX8-24, FR4-18i Feature: FCIP Function: FCIP I/O Probability: High Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000320772 Technical Severity: Medium Summary: Class three frame discards observed when supportshow is executed Symptom: Customer may observe SCSI/IO errors when supportsave is executed on specific platforms such as the Brocade 300 or 5300 Feature: Field Escalation Function: ASIC Driver Probability: Medium Found in Release: FOS6.1.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000325588 Technical Severity: Medium Summary: Status of fwfrucfg and trackchangesset are not overwritten by configDownload Symptom: If customer has updated FRU config status or trackchangeset status, then uploaded the config file, followed by a configdefault, the status will not be restored upon download of the config file. Feature: FABRIC WATCH Function: Other Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000329521 Technical Severity: Medium Summary: FICON MIB traps missing .21 in their OID Symptom: This will result in a mismatch between FICON link incident MIB trap OID prefix sent from a switch with the actual OID values for these traps as per the MIB definition and MIB reference manual. Feature: Field Escalation Function: SNMP Probability: High Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000333616 Technical Severity: Medium Summary: IPv6 named Certificate Signing Request (CSR) files may not be FTP'd to some Windows based ftp servers Symptom: Windows servers do not accept ":" character in the filename which is present in IPv6 CSR filenames, thus transfer will fail. Feature: Field Escalation Function: Security Probability: Low Found in Release: FOS6.3.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000335302 Technical Severity: Medium Summary: FOS v6.4.1a has SWBD folder of unsupported embedded switch type. Symptom: Could result in unpredictable platform behavior after FW download Feature: Infrastructure Function: Other Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.2 Defect ID: DEFECT000340526 Technical Severity: Medium Summary: rpcd killed and restarted Symptom: Termination of rpcd daemon and HA state out of sync. Feature: Field Escalation Function: Panic / OOM Probability: Low Found in Release: FOS6.4.
Closed with Code Change in Fabric OS v6.4.1b – GA March 2, 2011 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of March 2, 2011 in Fabric OS v6.4.1b. Defect ID: DEFECT000283566 Technical Severity: High Summary: Continuous SNMPd FFDC observed on switch during SNMP queries Symptom: SNMPd FFDC will occur if a rare race condition is encountered Feature: Field Escalation Function: Management Embedded Probability: Low Found in Release: FOS6.1.
Close with Code Change in Fabric OS v6.4.1b Defect ID: DEFECT000327226 Technical Severity: High Summary: After executing shut/no shut on port-channel member, sync is not regained preventing port from coming back online Symptom: Link member is lost from trunk group Feature: CEE-Infrastructure Function: ANVIL DRIVER Probability: Medium Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.1b Defect ID: DEFECT000288021 Technical Severity: Medium Summary: Unable to login to the switch with accounts that are present in the switch database. Symptom: User unable to launch Web Tools with user account from switch database when user configured LDAP/Radius as primary and switch database as secondary for validation. Workaround: Use CLI or Use LDAP/Radius account. Feature: FOS Security Function: Radius Probability: Medium Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.1b Defect ID: DEFECT000323031 Technical Severity: Medium Summary: Removal of FCR binding may cause backbone to edge host/target discovery issues Symptom: Not likely to encounter, however if it occurs, customer will not be able to execute backbone to edge IO. Workaround: Reboot the backbone FCRs. Feature: FC Services Function: Other Probability: Low Found in Release: FOS6.4.
Closed with Code Change in Fabric OS v6.4.1a - GA December 14, 2010 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of December 14, 2010 in Fabric OS v6.4.1a.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000303239 Technical Severity: High Summary: Observed fspf daemon termination when performing portenable of E-ports in a FCR setup with FCIP VEX links. Symptom: After port disable/enable or cable pull disruptive testing, observe some switches are not present in fabricshow, some VEx ports remain disabled (Switch not ready for EX_Ports) Feature: FC Services Function: FSPF Probability: Medium Found in Release: FOS6.4.0 Where Else Fixed: FOS6.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000319033 Technical Severity: High Summary: Observed memory allocated to TSD was increasing over time which could potentially impact switch over an extended duration Symptom: Standby CP may reboot, and under some situations the active CP may fail and an HA Failover may be observed Feature: Fabric Infrastructure Function: Time Server Probability: Low Found in Release: FOS6.4.1_fcoe Where Else Fixed: FOS6.4.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000322883 Technical Severity: High Summary: Brocade 48000 running FOS v6.2.0x are unable to upgrade to v6.3.x when a GE port is present and is persistently disabled. Symptom: After a firmware download from FOS 6.2 to FOS 6.3, active CP may fail to come online completely. After rebooting CP to recover, if CP is downgraded to FOS v6.2 code again, the CP is left with an invalid configuration.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000324848 Technical Severity: High Summary: Any 8G blade or 8G switch running with FOS 6.4.0, 6.4.0a, 6.4.0b, 6.4.0c and 6.4.1 could observe a loss of connectivity on a port or trunked ISL causing all traffic entering the switch or the blade to be dropped. Symptom: When there is a trunk consisting of 2 or more ports, other ports on the same ASIC chip are improperly programmed with the same table entry in ASIC routing table as trunk ports. .
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000281918 Technical Severity: Medium Summary: Switch report VERIFY - Failed expression: ag_descp != NULL,file = ms_telnetcmds.c, line = 525, user mode args = 140, 0" Symptom: With AG fabric, DXFM/FM/SMI proxy switch will send GAGI request to another switch in the fabric with Brocade_AG query. Sometime it triggers verify and floods the raslog. The continuous verify could cause other side effects such as high cpu load and/or switch panic.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000301856 Technical Severity: Medium Summary: Boot Over SAN fails with switch port set to 8GB on Brocade 5470. Symptom: A 3rd party device connected to a Brocade 5470 takes a long time to come online and boot over SAN can fail. Feature: Embedded Platform Services Function: BR 5470 Integration Probability: Low Found in Release: FOS6.3.1 Where Else Fixed: FOS6.3.2 b, FOS6.4.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000312579 Technical Severity: Medium Summary: zoned panic during hafailover during firmwaredownload on Brocade 48000 in IM2 mode Symptom: When upgrading from Fabric OS v6.3.x to v6.4.x, the switch experienced a panic on zoned after the initial failover with the new CP at v6.4.x with a cold recovery of the switch. This only impacts Brocade 48000 running IM2 mode.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000316023 Technical Severity: Medium Summary: After hareboot/hafailover, LED for trunked F ports turns off Symptom: LED transitions from steady green to off for online trunked F-ports after hareboot/hafailover or code upgrade. Feature: 4G ASIC Driver Function: ASIC Driver Probability: Medium Found in Release: FOS7.0.0 Where Else Fixed: FOS6.3.2 b, FOS6.4.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000320157 Technical Severity: Medium Summary: firmwarecommit component of firmwaredownload takes significantly longer when the switch does not have ipv4 address configured. Symptom: On a switch with ipv6 address only, firmwarecommit alone (following firmwaredownload through the ipv6 interface) takes 20+ minutes.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000323250 Technical Severity: Medium Summary: Blade fault observed during heavy tape IO stress for DataFort compatible tapes. Symptom: DataFort compatible tapes under heavy stress tape I/O jobs may lead to faulty Brocade encryption blade or Brocade encryption switch. Feature: Data Security Function: Tape Encryption Probability: Low Found in Release: FOS6.3.2 Where Else Fixed: FOS6.4.
Close with Code Change in Fabric OS v6.4.1a Defect ID: DEFECT000326252 Technical Severity: Medium Summary: Encryption group having more than one node, cryptocfg commit hangs if the configuration to be committed is having more than 560 LUNs in a single container. Symptom: Adding/Configuring more than 560 LUNs into a CTC followed by “cryptocfg commit” to commit the configuration across an Encryption Group results in the operation hanging.
Closed with Code Change in Fabric OS v6.4.1 - GA October 7, 2010 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of October 7, 2010 in Fabric OS v6.4.1. Defect ID: DEFECT000319291 Technical Severity: Critical Summary: In a dual Inter-fabric Link (IFL) FCR fabric with LSAN Matrix configured and LSAN binding enabled, disabling the EX_Port for one of the IFLs causes all FCR devices to be removed from the name server database.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000269222 Technical Severity: High Summary: 8G switches, and directors with an 8G blade in slot 1, see frame drops in the fabric when there are Ex/VEx ports configured Symptom: If there is an Ex/VEx port configured in the same ASIC chip as an F/E port with EGID 0, hosts cannot see the targets and customer may observe poor performance in the fabric.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000284426 Technical Severity: High Summary: Due to firmware being out of synch with the FPGA version, a Brocade 5470 may get extremely high enc out errors on ports connected to 3rd party HBAs, which may cause link related problems to that HBA. Symptom: High "enc out" errors show up in the counters when running the porterrshow CLI command.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000288870 Technical Severity: High Summary: Converged Network Adapter (CNA) cannot login during shut/no shut operation Symptom: CNA is not able to log in to Brocade 8000 / FCOE10-24 blade. Feature: CEE-FCOE Function: FCOE DRIVER Probability: Low Found in Release: FOS6.3.1_cee Where Else Fixed: FOS6.3.2, FOS6.4.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000296266 Technical Severity: High Summary: When Auto Port Configuration is enabled on an Access Gateway, switch will lock the port as an N_Port if no FLOGI received within timeout period, then disable it after receiving ELS rejects Symptom: On a Brocade 5480 with the Auto Port Configuration (APC) feature enabled, ports will become locked down as N_Ports if there is no FLOGI sent by an attached device within the timeout period.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000301260 Technical Severity: High Summary: Host/Target unable to establish routes across VEX-VE Link Symptom: Due to timing issue, hosts will not be able to access targets for any operational purposes when the NUMBER of FCIP Circuit configuration on one side of the FCIP Tunnel does not match the other side. Feature: FCIP Function: FCIP I/O Probability: Low Found in Release: FOS6.4.0 Where Else Fixed: FOS6.4.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000304922 Technical Severity: High Summary: Compact flash failure handling needs enhanced to detect and proactively trigger an hafailover when a bad flash part is detected. Symptom: Compact flash can sometimes fail silently, so customer only sees critical daemon failures, which then trigger a failover. Occasionally no failure is seen at all when this happens, the switch will continue running but does not produce any logs.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000274403 Technical Severity: Medium Summary: One directional route problem in fabric prevents local switch communicating to remote switch, causing remote switch to disable local switch without any notification. Symptom: Switch goes to disabled state without any reason logged, and with no user action. Customer sees messages indicating RTWR has reached max retries in RASLOG.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000287990 Technical Severity: Medium Summary: Value of 0xffffffff in the config file for the N_Port topology field causes an error and fails the configdownload operation. Symptom: Using the configdownload command on a BES in AG mode with SRDF enabled fails with the following error: strtoul failed str 0xffffffff, errno =2 aglib_strtobm failed for ag.pg.pgporttopo.0 value = 0xffffffff configDownload: agImport() failed key = ag.pg.pgporttopo.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000297954 Technical Severity: Medium Summary: Due to heartbeat counter communication problems between the Control Processor (CP) and FR4-18i blade, the CP and blade can lose sync, causing the blade to be rebooted. Symptom: FCIP-5030 messages are seen in the internal RASLOG, indicating that the FR4-18i blade has lost heartbeat with the Control Processor (CP).
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000299528 Technical Severity: Medium Summary: When running tape operations using tape pipelining in a Brocade 7800 or FX8-24 blade, the FCP_CONF command may be dropped, causing the tape operation to fail. Symptom: I Series I/O stops with tape pipelining enabled, causing tape operations running over a Brocade 7800 or FX8-24 blade to not complete successfully. Feature: FCIP Function: Emulation Probability: Low Found in Release: FOS6.3.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000302032 Technical Severity: Medium Summary: Port is reinitialized multiple times during unstable signal/port fault period when connected to certain servers that do not cut light when rebooting. Symptom: With certain very specific servers that do not cut off light during reboot, the switch cannot bring an F_Port on line for a long time. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.3.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000304033 Technical Severity: Medium Summary: On a Brocade 5470, setting the port to fixed 8GB causes boot over SAN to fail with some 3rd party HBAs. Symptom: Boot over SAN with 3rd party 8G HBA fails with port speed configured fixed to 8GB. Feature: 8G ASIC Driver Function: PORT Probability: Medium Found in Release: FOS6.3.1 Where Else Fixed: FOS6.4.1, FOS6.3.
Close with Code Change in Fabric OS v6.4.1 Defect ID: DEFECT000313466 Technical Severity: Medium Summary: SCSI command frames are dropped through IFL links in FCR Fabric. Symptom: If a Brocade switch performs an HA Failover at the same time as an device is continuously issuing a PLOGI to an unknown port, switch may drop SCSI command frames across IFL connections after hafailover. SCSI data frames pass through.
Close with Code Change in Fabric OS v6.4.0c Closed with Code Change in Fabric OS v6.4.0c - GA September 2, 2010 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of September 2, 2010 in Fabric OS v6.4.0c. Defect ID: DEFECT000301286 Technical Severity: High Summary: Routes are not properly redistributed after trunk group loses a trunk member.
Close with Code Change in Fabric OS v6.4.0c Defect ID: DEFECT000315751 Summary: FCIP tunnel bounces on workload start Symptom: Traffic disruption is observed. Technical Severity: High Workaround: Enable some sort of FICON emulation (XRC or Tape Read/Write Pipelining). Feature: FCIP Function: FCIP Port Probability: High Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.0c Defect ID: DEFECT000307117 Technical Severity: Medium Summary: Unable to form an ISL with AP7420 platform Symptom: A switch running FOS6.4.0 cannot form an ISL with AP7420 platform Workaround: Connect AP7420 to a platform that is running an earlier release of FOS than FOS6.4.0 (e.g. FOS6.3.0). Feature: FC Services Function: Fabric Probability: Low Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.0c Defect ID: DEFECT000313149 Technical Severity: Medium Summary: Receiving emulation error 60 during FICON read tape emulation. Symptom: Attention status received. Workaround: When FICON path control blocks are stuck at invalid state, disable the tunnel. If issues are occurring with FICON emulation and ESCON devices, disable FICON Emulation. In the case of the failed tape job, resubmit it.
Closed with Code Change in Fabric OS v6.4.0b - GA June 25, 2010 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of June 25, 2010 in Fabric OS v6.4.0b. Defect ID: DEFECT000283335 Technical Severity: High Summary: A device with a node WWN of zero connected to an NPIV port queried by CALD causes the switch to panic and reboot Symptom: CALD causing switch to panic and reboot about every 20-30mins.
Close with Code Change in Fabric OS v6.4.0b Defect ID: DEFECT000301612 Technical Severity: High Summary: VE port "aptpolicy port_based" did not change internal policy Symptom: When an FX8-24 and a FS8-18 are installed in the same chassis and the user attempts to set the routing policy to port-based, it may not take effect and the internal policy could remain as exchanged based routing. Feature: 8G Platform Services Function: Routing Probability: High Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.0b Defect ID: DEFECT000270825 Technical Severity: Medium Summary: Expose all 64 bit port stats counter through SNMP Symptom: 64 bit port stats is only available in CLI via portStats64Show, it's not exposed through SNMP. Feature: Mgmt Embedded - SNMP Function: Other Probability: Low Found in Release: FOS6.4.0 Defect ID: DEFECT000273725 Technical Severity: Medium Summary: Detected termination of webd and triggered call home event.
Close with Code Change in Fabric OS v6.4.0b Defect ID: DEFECT000298268 Technical Severity: Medium Summary: I Series tape I/O stops with tape pipelining enabled Symptom: Tape I/O with I Series server is not possible with tape pipelining enabled. Workaround: Disable / do not enable tape pipelining. Feature: FCIP Function: FCIP I/O Probability: Medium Found in Release: FOS6.4.
Close with Code Change in Fabric OS v6.4.0b Defect ID: DEFECT000300759 Technical Severity: Medium Summary: Addition of End-to-End Monitors through DCFM or CLI will fail after an HA Failover if Monitors were installed on the switch before the failover. Symptom: On a Condor 2 Platform, if the user has End-to-End Monitors installed and then performs an HA Failover, he cannot further install any new Monitors on chips(s) other than on which End-to-End Monitors were already configured prior to the Failover.
Close with Code Change in Fabric OS v6.4.0b Defect ID: DEFECT000302002 Technical Severity: Medium Summary: Unable to disable default zone from Mi10k in interop fabric(FOS and Mi10k) in IM2 mode Symptom: After a zone merge failure between Mi10k and FOS switches, disable Default zone from Mi10k, throws error as "Error: Zone Activation failed due to error in pushing the data to the rest of the fabric", need a switch reboot to recover.
Closed with Code Change in Fabric OS v6.4.0a - GA June 4, 2010 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of June 4, 2010 in Fabric OS v6.4.0a.
Closed with Code Change in Fabric OS v6.4.0a Defect ID: DEFECT000297793 Technical Severity: High Summary: Data encryption, name server fails to show the existence of a specific virtual initiator Symptom: As a result of an external FC port experiencing an excessive number of encoding CRC errors the internal ports are faulted incorrectly by switch firmware, hence a data encryption virtual initiator associated with the internal port fails to appear in name server.
Closed with Code Change in Fabric OS v6.4.0a Defect ID: DEFECT000298730 Technical Severity: High Summary: A LUN sized > 2TB cannot be configured for encryption with the -newLUN option Symptom: There is a potential for hosts to overwrite encryption metadata for encrypted LUNs where Read Capacity (16) is used to determine max LUN LBA (LUNs greater than 2TB in size). Workaround: Do not configure LUNs for encryption, using the -newLUN option if the LUN size is greater than 2TB.
Closed with Code Change in Fabric OS v6.4.0a Defect ID: DEFECT000281212 Technical Severity: Medium Summary: In AG mode, N-Port failover results in F-Ports with attached hosts getting stuck as G_Port Symptom: F-Ports get stuck as G-Ports after AG N-Port failover.
Closed with Code Change in Fabric OS v6.4.0a Defect ID: DEFECT000290784 Technical Severity: Medium Summary: Abort in Read emulation if Attention status received between status and status accept Symptom: IFCCs during Tape Read processing. Workaround: Disable FICON Emulation Feature: FCIP Function: FCIP I/O Probability: Medium Found in Release: FOS6.3.
Closed with Code Change in Fabric OS v6.4.0a Defect ID: DEFECT000299335 Technical Severity: Medium Summary: FICON emulation, core hangs during error recovery Symptom: After an FCIP link failure, an FFDC will occur and some traffic across remaining FCIP links will continue to be disrupted. Feature: FCIP Function: Emulation Probability: High Found in Release: FOS6.4.0 Defect ID: DEFECT000300065 Technical Severity: Medium Summary: Data Encryption, Manual HA failback command on FOS v6.4.
Appendix: Additional Considerations for FICON Environments This appendix includes supplemental information for users deploying FOS-based platforms in FICON environments. The DCX-4S is only supported for FICON in Brocade Native Mode (interopmode 0) and therefore is not supported for interoperability with M-EOS platforms. Multiple 10 Gb/sec ISLs and FCIP links can load-share between cascaded FICON directors/switches but do not load balance in a FICON configuration.
Area Manageability Comments It is suggested that Port Fencing be used to avoid taking ports down for normal fabric events. The recommended fencing criteria and settings are: Criteria Value ITW (Invalid Transmission Words) 25 CRC (Cyclical Redundancy Check) 3 Protocol Errors 2 State Change 7 Note: In a FICON environment, the time base polling interval MUST be set to one minute for granular control and response. By default, Port Fencing time base is set to one hour.
Interoperability Within a fabric, current major releases will work with previous major releases on the same platform. When cascading switches, it is recommended to keep all switches in the fabric at the same code level. Although not expressly prohibited, having two switches in the same fabric that differ by more than one major FOS release level is not recommended. For example, a switch at FOS v6.4.2a connected to another switch at v6.4.0c is OK. Connecting a switch running FOS v6.4.