Brocade Fabric OS Troubleshooting and Diagnostics Guide v6.2.0 (53-1001187-01, April 2009)
106 Fabric OS Troubleshooting and Diagnostics Guide
53-1001187-01
Port information
13
Free_buffer: 0 Address_err: 0
Overrun: 0 Lr_in: 3
Suspended: 0 Lr_out: 0
Parity_err: 0 Ols_in: 0
2_parity_err: 0 Ols_out: 3
CMI_bus_err: 0
Port part of other ADs: No
See the Fabric OS Command Reference for additional portShow command information, such as
the syntax for slot or port numbering, displaying IP interfaces on a GbE port, or displaying FCIP
tunnel connection or configuration information.
Displaying the port statistics
1. Connect to the switch and log in as admin.
2. At the command line, enter the portStatsShow command.
Port statistics include information such as the number of frames received, number of frames sent,
number of encoding errors received, and number of class 2 and class 3 frames received.
See the Fabric OS Command Reference for additional portStatsShow command information, such
as the syntax for slot or port numbering.
brcd5300:admin> portstatsshow 68
stat_wtx 113535 4-byte words transmitted
stat_wrx 22813 4-byte words received
stat_ftx 9259 Frames transmitted
stat_frx 821 Frames received
stat_c2_frx 0 Class 2 frames received
stat_c3_frx 821 Class 3 frames received
stat_lc_rx 0 Link control frames received
stat_mc_rx 0 Multicast frames received
stat_mc_to 0 Multicast timeouts
stat_mc_tx 0 Multicast frames transmitted
tim_rdy_pri 0 Time R_RDY high priority
tim_txcrd_z 0 Time TX Credit Zero (2.5Us ticks)
time_txcrd_z_vc 0- 3: 0 0 0 0
time_txcrd_z_vc 4- 7: 0 0 0 0
time_txcrd_z_vc 8-11: 0 0 0 0
time_txcrd_z_vc 12-15: 0 0 0 0
er_enc_in 0 Encoding errors inside of frames
er_crc 0 Frames with CRC errors
er_trunc 0 Frames shorter than minimum
er_toolong 0 Frames longer than maximum
er_bad_eof 0 Frames with bad end-of-frame
er_enc_out 0 Encoding error outside of frames
er_bad_os 0 Invalid ordered set
er_c3_timeout 0 Class 3 frames discarded due to timeout
er_c3_dest_unreach 0 Class 3 frames discarded due to destination
unreachable
er_other_discard 0 Other discards
er_type1_miss 0 frames with FTB type 1 miss
er_type2_miss 0 frames with FTB type 2 miss
er_type6_miss 0 frames with FTB type 6 miss
er_zone_miss 0 frames with hard zoning miss
er_lun_zone_miss 0 frames with LUN zoning miss
er_crc_good_eof 0 Crc error with good eof