Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

2-8 Fabric OS Message Reference
Publication Number: 53-1000242-01
AUTH-1025
2
AUTH-1025
Message
Probable
Cause
Indicates the authentication process failed to get the expected information during the specified
authentication phase.
Recommended
Action
Usually this problem is transient. The authentication might fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
AUTH-1027
Message
Probable
Cause
Indicates that the authentication process failed to select an authentication value (that is, DH Group,
hash value, or protocol type) from a receiving payload for the specified authentication phase. This
indicates that the local switch does not support the specified authentication value.
Recommended
Action
Check the authentication configuration and reset the supported value if needed using the authUtil
command.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
AUTH-1028
Message
<timestamp>, [AUTH-1025], <sequence-number>,, ERROR, <system-name>,
Failed to get <data type> during <authentication phase>: port <port
number>
<timestamp>, [AUTH-1027], <sequence-number>,, ERROR, <system-name>,
Failed to select <authentication value> during <authentication
phase>: value <value> port <port number>.
<timestamp>, [AUTH-1028], <sequence-number>,, ERROR, <system-name>,
Failed to allocate <data type> for <operation phase>: port <port
number>