Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 28-5
Publication Number: 53-1000242-01
HIL-1202
28
HIL-1202
Message
Probable
Cause
Indicates that the specified fan speed (in RPM) has fallen below the minimum threshold.
Recommended
Action
Replace the fan FRU.
Severity ERROR
HIL-1203
Message
Probable
Cause
Indicates that the specified fan speed (in RPM) has risen above the maximum threshold. A high speed
does not necessarily mean that the fan is faulty.
Recommended
Action
Run the tempShow command to verify that the switch temperatures are within operational range. Refer
to the hardware reference manual for the temperature range of your switch.
Make sure that the area is well ventilated and that the room temperature is within operational range of
your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.
Run the fanShow command to monitor the speed of the fan generating this error.
If the fan continues to generate this message, replace the fan FRU.
Severity ERROR
HIL-1204
Message
Probable
Cause
Indicates that the specified fan speed (in RPM) has fallen below the minimum threshold. This message
is specific to nonbladed switches and is not applicable to the SilkWorm 12000, 24000, or 48000.
<timestamp>, [HIL-1202], <sequence-number>,, ERROR, <system-name>,
Blower <blower number> faulted, speed (<measured speed> RPM) below
threshold.
<timestamp>, [HIL-1203], <sequence-number>,, ERROR, <system-name>,
Fan <fan number> faulted, speed (<measured speed> RPM) above
threshold.
<timestamp>, [HIL-1204], <sequence-number>,, ERROR, <system-name>,
Fan <fan number> faulted, speed (<measured speed> RPM) below
threshold.