Indicates that the state of the power supply has changed from faulty to functional, or from functional to
faulty.
Recommended
Action
If the power supply is functioning correctly, no action is required.
If the power supply is functioning below the acceptable boundary, verify that it is seated correctly in the
chassis. Run the psShow command to view the status of the power supply. If the power supply
continues to be a problem, replace the faulty power supply.
Severity INFO
FW-1010
Message
Probable
Cause
Indicates that the power supply is faulty. The power supply is not producing enough power.
Recommended
Action
Verify that you have installed the power supply correctly and that it is correctly seated in the chassis. If
the problem persists, replace the faulty power supply.
Severity WAR NIN G
FW-1011
Message
Probable
Cause
Indicates that the power supply is functioning properly.
Recommended
Action
Set the high boundary above the normal operation range.
<timestamp>, [FW-1009], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1010], <sequence-number>,, WARNING, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1011], <sequence-number>,, INFO, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low