Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 18-15
Publication Number: 53-1000242-01
FCR-1048
18
FCR-1048
Message
Probable
Cause
Indicates the specified credit type was not set.
Recommended
Action
Setting port credits failed. Run the portEnable command.
If the problem persists try rebooting the switch.
If the message persists, collect switch information using the supportShow command, and contact your
switch service provider.
Severity ERROR
FCR-1049
Message
Probable
Cause
Indicates that an incoming ELP command was issued and it is not supported.
Recommended
Action
Run the portEnable and portDisable commands to enable and disable the port.
If the problem persists contact your switch service provider.
Severity ERROR
FCR-1053
Message
Probable
Cause
Indicates that the specified port was disabled because of a mismatched configuration parameter.
Recommended
Action
Use the specified disable reason. Look for a possible configuration parameter mismatch between the
EX port and the switch at other end of the link.
Severity WAR NIN G
<timestamp>, [FCR-1048], <sequence-number>,, ERROR, <system-name>,
On EX port (<port number>) setting port <credit type> credits
failed.
<timestamp>, [FCR-1049], <sequence-number>,, ERROR, <system-name>,
EX port (<port number>) received an ELP command that is not
supported.
<timestamp>, [FCR-1053], <sequence-number>,, WARNING, <system-
name>, Port <port number> was disabled, <disable reason>.