Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 5-3
Publication Number: 53-1000242-01
BM-1006
5
Severity WAR NIN G
BM-1006
Message
Probable
Cause
The policy of the specified blade is to persistently disable all ports the first time the blade is detected, so
either:
The blade was detected for the first time in this slot
The blade was configured under a different mode
Recommended
Action
Configure the blade and persistently enable the ports.
Severity INFO
BM-1007
Message
Probable
Cause
The new blade requires these port configurations to be cleared. The blade was detected for the first time
after an FR4-18i was previously configured in the same slot.
Recommended
Action
No action is required.
Severity INFO
BM-1008
Message
Probable
Cause
The automatic firmware upgrade on the blade has failed because the blade firmware version was
detected to be different from CP firmware version due to a firmware upgrade.
Recommended
Action
Issue the firmwareDownload command to recover the blade.
<timestamp>, [BM-1006], <sequence-number>,, INFO, <system-name>,
Blade is not configured. Persistently disabling all ports for blade
in slot <Slot number>
<timestamp>, [BM-1007], <sequence-number>,, INFO, <system-name>,
Clearing EX/VEX port configuration for all ports for blade in slot
<Slot number>
<timestamp>, [BM-1008], <sequence-number>,, WARNING, <system-name>,
Download of blade firmware failed for blade in slot <slot>. Reissue
firmwaredownload to recover.