Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

3-12 Fabric OS Message Reference
Publication Number: 53-1000242-01
BL-1030
3
Recommended
Action
No action is required.
Severity INFO
BL-1030
Message
Probable
Cause
Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded
and resulted in the cold upgrade. As part of the upgrade, all the GigE/FCIP data elements were reset.
Recommended
Action
No action is required.
Severity INFO
BL-1031
Message
Probable
Cause
Indicates that link timeout occurred in one of the backend internal ports.
Recommended
Action
Power cycle the blade or run the slotPowerOff and slotPowerOn commands.
Severity CRITICAL
BL-1032
Message
<timestamp>, [BL-1030], <sequence-number>,, INFO, <system-name>,
All GigE/FCIP ports on the switch will be reset as part of the
firmware upgrade.
<timestamp>, [BL-1031], <sequence-number>,, CRITICAL, <system-
name>, Link timeout in internal port (slot <Slot number>, port <Port
number>) resulted in blade fault. Use slotpoweroff/slotpoweron to
recover the blade
<timestamp>, [BL-1032], <sequence-number>,, CRITICAL, <system-
name>, (slot <slot number>,bitmap 0x<object control flags(bitmap)>)
ports never came up ONLINE (reason <reason for port disable>, state
<status of the blade>). Disabling Slot.