Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)
Table Of Contents
- Contents
- About This Document
- Using Fabric OS Commands
- Fabric OS Commands
- aaaConfig
- ad
- ag
- agshow
- aliAdd
- aliCreate
- aliDelete
- aliRemove
- aliShow
- aptPolicy
- auditCfg
- authUtil
- bannerSet
- bannerShow
- bcastShow
- bladeBeacon
- bladeDisable
- bladeEnable
- burninErrClear
- burninErrShow
- burninLevel
- burninStatus
- cfgActvShow
- cfgAdd
- cfgClear
- cfgCreate
- cfgDelete
- cfgDisable
- cfgEnable
- cfgMcdtmode
- cfgRemove
- cfgSave
- cfgSaveActiveToDefined
- cfgShow
- cfgSize
- cfgTransAbort
- cfgTransShow
- chassisConfig
- chassisName
- chassisShow
- cliHistory
- configDefault
- configDownload
- configList
- configRemove
- configShow
- configUpload
- configure
- dataTypeShow
- date
- dbgShow
- defZone
- diagClearError
- diagDisablePost
- diagEnablePost
- diagHelp
- diagPost
- diagRetry
- diagSetBurnin
- diagSetCycle
- diagShow
- diagSkipTests
- diagStopBurnin
- dbgShow
- distribute
- dlsReset
- dlsSet
- dlsShow
- dnsConfig
- enclosureShow
- errClear
- errDelimiterSet
- errDump
- errFilterSet
- errModuleShow
- errShow
- exit
- fabPortShow
- fabRetryShow
- fabricLog
- fabricPrincipal
- fabricShow
- fabStatsShow
- fabSwitchShow
- fanDisable
- fanEnable
- fanShow
- fastboot
- fastwritecfg
- fcipChipTest
- fcipHelp
- fcipPathTest
- fcLunQuery
- fcPing
- fcpLogClear
- fcpLogDisable
- fcpLogEnable
- fcpLogShow
- fcpProbeShow
- fcpRlsShow
- fcrBcastConfig
- fcrChipTest
- fcrConfigure
- fcrFabricShow
- fcrLsanCount
- fcrLsanMatrix
- fcrPathTest
- fcrPhyDevShow
- fcrProxyConfig
- fcrProxyDevShow
- fcrResourceShow
- fcrRouterPortCost
- fcrRouteShow
- fcrXlateConfig
- fddCfg
- fdmiCacheShow
- fdmiShow
- ficonClear
- ficonCupSet
- ficonCupShow
- ficonHelp
- ficonShow
- fipsCfg
- firmwareCommit
- firmwareDownload
- firmwareDownloadStatus
- firmwareKeyShow
- firmwareKeyUpdate
- firmwareRestore
- firmwareShow
- fosConfig
- fruReplace
- fspfShow
- fwAlarmsFilterSet
- fwAlarmsFilterShow
- fwClassInit
- fwConfigReload
- fwConfigure
- fwFruCfg
- fwHelp
- fwMailCfg
- fwPortDetailShow
- fwSamShow
- fwSet
- fwSetToCustom
- fwSetToDefault
- fwShow
- h
- haDisable
- haDump
- haEnable
- haFailover
- haShow
- haSyncStart
- haSyncStop
- help
- historyLastShow
- historyMode
- historyShow
- httpCfgShow
- i
- iclCfg
- ifModeSet
- ifModeShow
- interfaceShow
- interopMode
- iodDelayReset
- iodDelaySet
- iodDelayShow
- iodReset
- iodSet
- iodShow
- ipAddrSet
- ipAddrShow
- ipfilter
- iscsiCfg
- iscsiChipTest
- iscsiHelp
- iscsiPathTest
- iscsiPortCfg
- iscsiSessionCfg
- iscsiSwCfg
- islShow
- isnscCfg
- itemList
- killTelnet
- ldapCfg
- licenseAdd
- licenseHelp
- licenseIdShow
- licensePort
- licenseRemove
- licenseShow
- linkCost
- login
- logout
- lsanZoneShow
- lsDbShow
- memShow
- miniCycle
- msCapabilityShow
- msConfigure
- msPlatShow
- msPlatShowDBCB
- msPlClearDB
- msPlMgmtActivate
- msPlMgmtDeactivate
- msTdDisable
- msTdEnable
- msTdReadConfig
- myId
- nbrStateShow
- nbrStatsClear
- nodeFind
- nsAliasShow
- nsAllShow
- nsCamShow
- nsShow
- nsZoneMember
- passwd
- passwdCfg
- pathInfo
- pdShow
- perfAddEEMonitor
- perfAddIPMonitor
- perfAddReadMonitor
- perfAddRWMonitor
- perfAddSCSIMonitor
- perfAddUserMonitor
- perfAddWriteMonitor
- perfCfgClear
- perfCfgRestore
- perfCfgSave
- perfClearAlpaCrc
- perfDelEEMonitor
- perfDelFilterMonitor
- perfHelp
- perfMonitorClear
- perfMonitorShow
- perfSetPortEEMask
- perfShowAlpaCrc
- perfShowPortEEMask
- perfTTmon
- pkiCreate
- pkiRemove
- pkiShow
- policy
- portAlpaShow
- portBufferShow
- portCamShow
- portCfg
- portCfgAlpa
- portCfgCreditRecovery
- portCfgDefault
- portCfgEPort
- portCfgEXPort
- portCfgGPort
- portCfgISLMode
- portCfgLongDistance
- portCfgLPort
- portCfgNPIVPort
- portCfgNPort
- portCfgPersistentDisable
- portCfgPersistentEnable
- PortCfgQos
- portCfgShow
- portCfgSpeed
- portCfgTrunkPort
- portCfgVEXPort
- portCmd
- portDebug
- portDisable
- portEnable
- portErrShow
- portFlagsShow
- portLedTest
- portLogClear
- portLogConfigShow
- portLogDisable
- portLogDump
- portLogDumpPort
- portLogEnable
- portLogEventShow
- portLoginShow
- portLogPdisc
- portLogReset
- portLogResize
- portLogShow
- portLogShowPort
- portLogTypeDisable
- portLogTypeEnable
- portLoopbackTest
- portMirror
- portName
- portPerfShow
- portRouteShow
- portShow
- portStats64Show
- portStatsClear
- portStatsShow
- portSwap
- portSwapDisable
- portSwapEnable
- portSwapShow
- portTest
- portTestShow
- portTrunkArea
- portZoneShow
- powerOffListSet
- powerOffListShow
- psShow
- reboot
- routeHelp
- secActiveSize
- secAuthSecret
- secCertUtil
- secDefineSize
- secGlobalShow
- secHelp
- secPolicyAbort
- secPolicyActivate
- secPolicyAdd
- secPolicyCreate
- secPolicyDelete
- secPolicyDump
- secPolicyFCSMove
- secPolicyRemove
- secPolicySave
- secPolicyShow
- secStatsReset
- secStatsShow
- sensorShow
- setDbg
- setModem
- setVerbose
- sfpShow
- shellFlowControlDisable
- shellFlowControlEnable
- slotPowerOff
- slotPowerOn
- slotShow
- snmpConfig
- spinFab
- sshUtil
- statsClear
- stopPortTest
- supportFfdc
- supportFtp
- supportSave
- supportShow
- supportShowCfgDisable
- supportShowCfgEnable
- supportShowCfgShow
- switchBeacon
- switchCfgPersistentDisable
- switchCfgPersistentEnable
- switchCfgSpeed
- switchCfgTrunk
- switchDisable
- switchEnable
- switchName
- switchShow
- switchStatusPolicySet
- switchStatusPolicyShow
- switchStatusShow
- switchUptime
- switchViolation
- syslogdFacility
- syslogdIpAdd
- syslogdIpRemove
- syslogdIpShow
- sysShutDown
- systemVerification
- tempShow
- timeOut
- topologyShow
- traceDump
- trackChangesHelp
- trackChangesSet
- trackChangesShow
- trunkDebug
- trunkShow
- tsClockServer
- tsTimeZone
- turboRamTest
- upTime
- uRouteConfig
- uRouteRemove
- uRouteShow
- usbStorage
- userConfig
- userRename
- version
- wwn
- zone
- zoneAdd
- zoneCreate
- zoneDelete
- zoneHelp
- zoneObjectCopy
- zoneObjectExpunge
- zoneObjectRename
- zoneRemove
- zoneShow
- Primary FCS commands
- Control Processor Commands
- Command availability
- Index
552 Fabric OS Command Reference
53-1000599-02
psShow
2
psShow
Displays power supply status.
Synopsis psshow
Description Use this command to display the current status of the switch power supplies.
The status of each supply is displayed as:
OK Power supply functioning correctly.
absent Power supply not present.
unknown Unknown power supply unit installed.
predicting failure Power supply is present but predicting failure.
faulty Power supply present but faulty (no power cable, power switch turned off,
fuse blown, or other internal error).
For certain switch models, the OEM serial ID data displays after each power supply status line.
Operands none
Examples To view the status of the power supplies:
switch:admin> psshow
Power Supply #1 is OK
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000088
Power Supply #2 is faulty
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000162
Power Supply #3 is OK
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000120
Power Supply #4 is absent
See Also chassisShow, fanShow