Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
416 Fabric OS Command Reference
53-1000599-02
perfTTmon
2
To display the F_Port Top Talker output:
Switch:admin> perfttmon --show 1/2 pid
=====================================
Src_PID Dst_PID MB/sec
=====================================
0xa90800 0xa05200 6.926
0xa90800 0xa905ef 6.872
0xa905ef 0xa05200 6.830
0xa909d5 0xa05200 6.772
To delete the Fabric Mode Top Talker:
Switch:admin> perfttmon --del fabricmode
To add the Fabric Mode Top Talker:
Switch:admin> perfttmon --add fabricmode
To display to Fabric Mode Top Talker output:
Switch:admin> perfttmon --show dom 101 pid
======================================
Src_PID Dst_PID MB/sec
======================================
0xa908ef 0xa05200 6.926
0xa05200 0xa908ef 6.872
0xa905ef 0xa05200 6.830
0xa909d5 0xa05200 6.772
To delete the Fabric Mode Top Talker:
Switch:admin> perfttmon --del fabricmode
See Also none