Cisco MDS 9200 Series Hardware Installation Guide (OL-16188-01, April 2008)
B-6
Cisco MDS 9200 Series Hardware Installation Guide
OL-16188-01
Appendix B Technical Specifications
X2 Transceiver Specifications
X2 Transceiver Specifications
The Cisco MDS 9200 Series is compatible with X2 transceivers and cables that have SC connectors.
Each transceiver must match the transceiver on the other end of the cable in terms of wavelength, and
the cable must not exceed the stipulated cable length for reliable communications.
Use only Cisco X2 transceivers on the Cisco MDS 9200 Series. Each Cisco X2 transceiver is encoded
with the model information that enables the switch to verify that the SFP transceiver meets the
requirements for the switch.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
32-port 1-Gbps/2-Gbps Fibre
Channel module, DS-X9032
3.x 191 816 2.65 1.99 1.33 0.99
2.x and 1.x 200 855 2.78 2.08 1.39 1.04
16-port 1-Gbps/2-Gbps Fibre
Channel module, DS-X9016
3.x 210 897 2.92 2.19 1.46 1.09
2.x and 1.x 200 940 3.05 2.29 1.53 1.15
MSM-18/4 module
DS-X9304-18K9
3.2(1) 200 855 2.78 2.08 1.39 1.04
MSFM-18/4 module
DS-X9304-18FK9
3.2(1) 200 855 2.78 2.08 1.39 1.04
MPS-14/2 DS-X9302-14K9 3.x 200 854 2.78 2.08 1.39 1.04
2.x and 1.x 227 970 3.15 2.37 1.57 1.19
8-port IPS module
DS-X9308-SMIP
3.x 200 854 2.78 2.08 1.39 1.04
2.x and 1.x 220 940 3.05 2.29 1.53 1.15
4-port IPS module
DS-X9304-SMIP
3.x 160 683 2.22 1.67 1.11 0.83
2.x and 1.x 185 789 2.57 1.93 1.28 0.96
32-port SSM,
DS-X9032-SSM
3.x 281 1200 3.90 2.93 1.95 1.46
2.x and 1.x 295 1260 4.10 3.07 2.05 1.54
32-port ASM
DS-X9032-SMV
3.x 281 1200 3.90 2.93 1.95 1.46
2.x and 1.x 295 1260 4.10 3.07 2.05 1.54
CSM,
DS-X9560-SMC
3.x 200 854 2.78 2.08 1.39 1.04
2.x and 1.x 210 907 2.95 2.22 1.48 1.11
Table B-7 Power Requirements and Heat Dissipation for the 845-W Power Supply (continued)
Module Type /
Product Number SAN-OS Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
90 VAC
(amps)
120 VAC
(amps)
180 VAC
(amps)
240 VAC
(amps)