Brocade Fabric OS v7.0.2e Release Notes v1.0

Fabric OS v7.0.2e Release Notes v1.0 Page 6 of 53
Features
FOS v7.0.2 is a maintenance release that contains fixes for defects including those from FOS v7.0.1a and FOS
v7.0.1b patch releases. In addition this release includes the following features and enhancements
implemented in FOS v7.0.2:
D_Port Enhancements
o D_Port link saturation capabilityability to drive test traffic to saturate link utilization close to
line rate as part of D_Port test
Ability to assign individual ports of an optical ICL to logical switches
o Prior to FOS v7.0.2, in Virtual Fabrics enabled environment, an entire ICL port (which includes
four individual ports as part of a single QSFP) has to be associated with a single logical switch.
Starting with FOS v7.0.2, the individual ports within an optical ICL can be assigned to different
logical switches. This feature is applicable to the DCX8510 platforms.
Note:
Please note that if any individual port of a QSFP is part of the Base Switch, the
remaining ports of that QSFP cannot be assigned to any other logical switch.
Bottleneck detection enhancements - Decoupling of latency and congestion alerts
In FOS v7.x releases prior to FOS v7.0.2, when users enabled bottleneck alerts, it would enable
alerting for both congestion and latency bottleneck conditions. Starting with FOS v7.0.2 users can
choose to enable alerts only for latency bottleneck while not enabling alerts for congestion bottleneck
or vice versa. Users still have the option to enable alerts for both congestion and latency bottleneck
conditions.