Brocade Fabric OS v7.2.1a Release Notes v1.0 March 7, 2014 Document History Document Title Summary of Changes Publication Date Brocade Fabric OS v7.2.1a Release Notes v1.
© 2014 Brocade Communications Systems, Inc. All Rights Reserved. ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners.
Contents Overview ...................................................................................................................................................... 5 Resolution of Important Defects ............................................................................................................................. 5 Additional Hardware Platform Support ................................................................................................................... 5 New Features & Support ...
Virtual Fabrics ........................................................................................................................................................ 29 WebTools ................................................................................................................................................................ 29 Zoning ................................................................................................................................................................
Overview Fabric OS (FOS) v7.2.1a is a patch release based on FOS v7.2.1. All hardware platforms and features supported in FOS v7.2.1 are also supported in FOS v7.2.1a. This release also contains fixes for many defects including those from the FOS v7.2.0d patch releases. Due to the impact of defect 491192 and 494570, Brocade recommends all customers planning or using FOS v7.2.1 to upgrade to FOS v7.2.1a. Note: If customers are already running FOS v7.2.1 on their switches, and the “Custom.
Brocade Extended Fabrics—Provides greater than 10km of switched fabric connectivity at full bandwidth over long distances (depending on platform this can be up to 3000km). Note: If a port on 16G FC blades or a 16G switch is configured to operate at 10G speed, Extended fabrics license is not needed to enable long distance connectivity on that port. Brocade ISL Trunking— Provides the ability to aggregate multiple physical links into one logical link for enhanced network performance and fault tolerance.
With FOS v7.2, the Adaptive Networking license has become part of the base FOS firmware, and features under this license no longer require the license to be installed. Customers that wish to have these capabilities without purchasing the license are required to upgrade to FOS v7.2 or later. Brocade 6520 does not require the Adaptive Networking with QoS license to enable the capabilities associated with this license. These capabilities are included by default on the Brocade 6520.
10 1GbE ports and 1 10GbE port, or 2 10GbE ports On FC16-xx: Enables 10G FC capability on an FC16-xx blade in a slot that has this license On Brocade 6510, Brocade 6520: Enables 10G FC capability on Brocade 6510, Brocade 6520. This license is available on the DCX/DCX-4S/DCX 8510-8/DCX 8510-4 on an individual slot basis.
Temporary License Support The following licenses are available in FOS v7.
Supported Switches FOS v7.2.1 supports the following existing platforms: 300, 5100, 5300, 7800, VA-40FC, Brocade Encryption Switch, DCX, DCX-4S 6505, 6510, 6520, DCX 8510-8, DCX 8510-4 FC16-32, FC16-48, FC8-32E, FC8-48E, FX8-24, FS8-18 on DCX 8510-8/DCX 8510-4 FC8-16, FC8-32, FC8-48, FC8-64, FX8-24, FS8-18, FCOE10-24 on DCX/DCX-4S 5410, 5424, 5430, 5450, 5480, 5470, 5460, NC-5480 Support merged to FOS v7.2.
Switch operating system version Error numbers and messages received supportSave command output and associated files o For dual CP platforms running FOS v6.
FOS Migration Considerations This section contains important details to consider before migrating to or from this FOS release. FOS Upgrade and Downgrade Special Considerations DCX/DCX-4S units running any FOS v7.1.x or FOS v7.2.0x can be non-disruptively upgraded to FOS v7.2.1a. This upgrade is non-disruptive to both FC and FCoE traffic (when using FCOE10-24 blades). Any firmware activation on Brocade 7800, or DCX, DCX-4S, DCX 8510-8, DCX 8510-4 with FX8-24 will disrupt I/O traffic on the FCIP links.
Important Notes This section contains information that you should consider before you use this Fabric OS release. Brocade Network Advisor Compatibility Brocade Network Advisor greatly simplifies the steps involved in daily operations while improving the performance and reliability of the overall SAN and IP networking environment. Brocade Network Advisor unifies, under a single platform, network management for SAN, LAN and converged networks.
on version 12.1.5 or later. With JRE 1.7.0 update 51, users could see some browser warning messages that can be ignored. SMI Compatibility It is important to note that host SMI-S agents cannot be used to manage switches running FOS v7.2. If users want to manage a switch running FOS v7.2 using SMI-S interface, they must use Brocade Network Advisor’s integrated SMI agent.
Multi-Protocol Router Interoperability Brocade 7500 and FR4-18i blade V6.2.2 and higher 4 6 8 McDATA SANRouters 1620 and 2640 Not Supported NOS (VDX Platform) Interoperability Brocade VDX6710, VDX6720, VDX6730 NOS v2.1.1 or later7 Brocade VDX8770 NOS 3.0 or later Table Notes: 1 When routing to an M-EOS edge fabric using frame redirection, the M-EOS fabric must have a FOS-based product in order to configure the frame redirection zone information in the edge fabric.
SNMP Support Starting with FOS v7.2.0, the Fabric OS MIB Reference document is not updated. You can obtain the latest MIBs from the downloads area of MyBrocade site after logging in. For information about SNMP support in Fabric Operating System (FOS) and how to use MIBs, see the Fabric OS Administrator’s Guide. Obtaining the MIBs You can download the MIB files required for this release from the downloads area of the MyBrocade site.
Fabric OS v7.2 software is fully qualified and supports the blades for the DCX/DCX-4S noted in the following table: DCX/DCX-4S Blade Support Matrix 16-, 32-, 48- and 64-port 8Gbit port blades (FC8-16, FC8-32, FC8-48, FC8-64) Supported with FOS v6.0 and above (FC8-64 requires FOS v6.4) with any mix and up to 8/4 of each. No restrictions around intermix. FC10-6 Not supported on FOS v7.1 or later Intelligent blade Up to a total of 8/4 intelligent blades.
Fabric OS v7.2 software is fully qualified and supports the blades for the DCX 8510-8 and DCX 8510-4 noted in the table below. DCX 8510-8/DCX 8510-4 Blade Support Matrix FC16-32, FC16-48 16G FC blades FOS v7.0 or later. FC8-64 64 port 8Gbit port blade With any mix and up to 8/4 of each. No restrictions around intermix. Note: FC8-16, FC8-32, FC8-48 blades are not supported on DCX 8510 platforms. FC8-32E, FC8-48E FOS v7.0.1 or later. Intelligent blade Up to a total of 8/4 intelligent blades.
Power Supply Requirements for Blades in DCX/DCX-4S Blades Type of Blade FC10-61, FC816, FC8-32, FC 8-48, FC864 Port Blade FR4-18i1 FS8-18, FX8-24, FCOE10-24 DCX/DCX-4S DCX/DCX-4S @110 VAC (Redundant configurations) @200-240 VAC (Redundant configurations) 2 Power Supplies 2 Power Supplies Intelligent Blade Not Supported 2 Power Supplies Intelligent Blade Not Supported DCX: 2 or 4 Power Supplies Comments DCX-4S: 2 Power Supplies Distribute the Power Supplies evenly to 2 different AC con
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments Any combination of 8Gb or 16Gb ports with QSFP ICLs FC8-64, FC16-32, FC8-32E Port Blade 4 Power Supplie
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments 384 16Gb ports + QSFP ICLs FC16-32, FC16-48 Port Blade Not Supported 4 Power Supplies 200-240VAC: For
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-4 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-4 Backbone Hardware Reference Manual) Configured Blades Number of Ports Type of Blade DCX 8510-4 @110 VAC (Redundant configurations) DCX 8510-4 @200-240 VAC (Redundant configurations) Comments 96 ports max with QSFP ICLs FC16-32, FC8-32E Port Blade 2 Power Supplies 2 Power Supplies 1+1 redunda
If FOS v7.2 or later is factory installed (or net installed), Adaptive Networking features are always available. This matches the behavior of the Brocade 6520 and all products shipping with prior versions of FOS and with the Adaptive Networking license factory installed. Ports will come up in AE mode by default If the remote port supports QOS and is not explicitly disabled, the link will come up in QOS mode. Otherwise, the link will come up in normal mode.
Gen 5 platforms and blades are capable of setting an EHT value on an individual port basis. On 8G platforms EHT is set on an ASIC-wide basis, meaning all ports on a common ASIC will have the same EHT setting. Extra care should be given when configuring EHT on 8G platforms or Gen 5 platforms with 8G blades to ensure E_Ports are configured with an appropriate Hold Time setting. When using Virtual Fabrics and creating a new Logical Switch when running FOS v7.1.
Hot Code Load from FOS v7.1.x to FOS v7.2 or later is supported. Cryptographic operations and I/O will be disrupted but other layer 2 FC traffic will not be disrupted. When disk and tape CTCs are hosted on the same encryption engine, re-keying cannot be done while tape backup or restore operations are running. Re-keying operations must be scheduled at a time that does not conflict with normal tape I/O operations.
FCoE/DCB/CEE (FCOE10-24) When upgrading a DCX/DCX-4S with one or more FCOE10-24 blades from FOS v6.x to FOS v7.0.0 or later, the user should carefully review Chapter 5 of the FOS v7.0.0 Converged Enhanced Ethernet Administrator’s Guide. Ethernet L2 traffic with xSTP Hello timer set to less than or equal to 3 seconds may experience momentary traffic disruption during HA failover. Hot plugging a CP with firmware level less than FOS v6.3.
the same OUI will have unique last 3 bytes in WWN). However, if the participating switches have different OUIs but identical last three bytes in the switch WWNs, then the merge logic will fail to guarantee uniqueness of login group names. This will result in one of the login groups being dropped from the configuration. This means, no device can login to the login group that is dropped as a result of this name conflict. Users must create a new login group with a non-conflicting name to allow device logins.
The FC8-48 and FC8-64 blade support attachment of loop devices. Virtual Fabrics must be enabled on the chassis and loop devices may only be attached to ports on a 48-port or 64-port blade assigned to a non-Default Logical Switch operating with the default 10bit addressing mode (they may not be in the default Logical Switch). A maximum of 144 ports may be used for connectivity to loop devices in a single Logical Switch within a chassis in 10-bit dynamic area mode on DCX-4S.
Port Mirroring Port Mirroring is not supported on the Brocade 7800. Port Statistics On 16G capable ports, the enc_in (number of encoding errors inside of frames) and enc_out (number of encoding errors outside of frames) counters will not be updated when a port is operating at either 10G or 16G speed. This is due to the different encoding scheme used at 10G and 16G speeds when compared to 8G/4G/2G speeds.
There are limitations to zoning operations that can be performed from a FOS v6.x switch that is in the same fabric as a FOS v7.0 or later switch if the FOS v6.x switch is not running the recommended firmware version. Please see Fabric OS Interoperability section for details. Beginning with the FOS v6.2.0 release, all WWNs containing upper-case characters are automatically converted to lower-case when associated with a zone alias and stored as part of a saved configuration on a switch.
QSFP No: 8 Channel No:0 Identifier: 13 QSFP+ Connector: 12 MPO Parallel Optic Transceiver: 0000000000000000 16_Gbps id It is recommended that for directors with more than 300 E_Ports, the switch be disabled prior to executing the “switchCfgTrunk” command (used to disable or enable trunking on the switch). During non-disruptive firmware upgrades, E_Ports in R-RDY mode may cause some frame drops on the E-port links.
Defects Closed with Code Change in Fabric OS v7.2.1a This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as of March 7th, 2014, in Fabric OS v7.2.1a. Defect ID: DEFECT000461189 Technical Severity: High Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: Web Tools FOS7.2.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000475264 Technical Severity: High Probability: Medium Product: FOS Technology: Security Reported In Release: FOS7.1.1 Technology Area: Fabric Authentication FOS7.2.1a(Fixed) Closed In Release(s): Symptom: After password expiration in switches with multiple logical switches, excessive login failures may trigger repeated secd panics.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000484327 Technical Severity: High Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.1.0 Technology Area: FC-FC routing FOS7.2.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000488202 Technical Severity: High Probability: Medium Product: FOS Technology: Distance Reported In Release: FOS7.1.0 Technology Area: IPsec FOS7.2.1a(Fixed) Closed In Release(s): Symptom: FCIP Circuit bounces due to replay checks when running IPSec with unidirectional traffic from the lower order IP address to the higher IP address on the circuit.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000491192 Technical Severity: Critical Probability: Medium Product: FOS Technology: Traffic Management Reported In Release: FOS7.2.0 Technology Area: Routing FOS7.2.1a(Fixed) Closed In Release(s): Symptom: FOSv7.2.0, 7.2.0a, 7.2.0b, 7.2.0c, 7.2.1 with user defined logical switch, hosts may be unable to reach targets due to frames being corrupted or traffic flow may appear to stop.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000494570 Technical Severity: High Probability: High Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: Firmware upload/download FOS7.2.1a(Fixed) Closed In Release(s): Symptom: Upgrading to FOS7.2.0c (which contains a fix for defect 491192) with pre-existing user-defined logical switches may lead to fabric wide performance issue or hosts not being able to see targets after a slot offline event .
Closed with Code Change in Fabric OS v7.2.1 This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as of December 13, 2013 in Fabric OS v7.2.1. Note: these defects are formatted with an updated defect table structure applying to all new or previously unpublished defects. Defect ID: DEFECT000415126 Technical Severity: High Probability: High Product: FOS Technology: Management Reported In Release: FOS7.1.0 Technology Area: CLI Closed In Release(s): FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000455170 Technical Severity: Medium Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.1.0 Technology Area: CLI FOS7.2.1(Fixed) Closed In Release(s): Symptom: On a switch without license, while changing the date using "date" command will display: "No licenses installed." Even though date properly updated by the command.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000463819 Technical Severity: High Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.0.2 Technology Area: FC-FC routing Closed In Release(s): FOS7.2.1(Fixed) Symptom: Class 2 GPN_FT queries may fail with excessive targets (127 targets) in the fabric.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000467051 Technical Severity: Medium Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.0.2 Technology Area: Fabric Watch FOS7.2.1(Fixed) Closed In Release(s): Symptom: switchstatuspolicy shows incorrect port count which may impact the accuracy of switch status Condition: switchstatuspolicy incorrectly accounts for logical ports into the total physical port count.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000469507 Technical Severity: High Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.0.1 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: Tape backup jobs on encrypted tape may fail. Condition: Issue will be seen on Brocade Encryption Switch or FS8-18 blade with hosts and targets that doesn’t support SRR/FCP_CONF and tape pipelining is enabled for the tape LUN.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000474392 Technical Severity: Medium Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.1.0 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: In a BES environment with CTC, hosts may lose access to LUNs temporarily. Condition: Issue will be seen on Brocade Encryption Switch or FS8-18 blade when BES/FS8-18 acting as an N port device, aborted the PLOGI in advance.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000476595 Technical Severity: High Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.0.2 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: In a heavy I/O environment, tape mounts are rejected for LTO drives on encryption blade.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000478505 Technical Severity: Medium Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.1.0 Technology Area: Encryption Closed In Release(s): FOS7.2.1(Fixed) Symptom: During tape backups on an encrypted tape LUN, switch or blade might become faulty with message “BM-BC heartbeat dead. Sending blade fault”. Condition: Issue may be seen during continuous backup of uncompressible data to encrypted tape.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000482076 Technical Severity: High Probability: Medium Product: FOS Technology: Management Reported In Release: FOS7.1.0_blv Technology Area: Licensing Closed In Release(s): FOS7.2.1(Fixed) Symptom: While downloading firmware to 16G embedded switches using BNA 12.1.1, after a successful update of the first switch, an EGM license missing error is reported when attempting firmwaredownload on the second 16G embedded switch.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000435100 Technical Severity: Medium Summary: SNMPCONFIG is inconsistent on ISCSI settings Symptom: Disable ISCSI-mibcapability in FOSv6.3 and then upgraded to FOSv6.4, when the new firmware comes up, ISCSI- MIB is in disabled state and ISCSI-TRAPS are in enabled state. Risk of Fix: High Probability: Medium FOS Software Feature: Function: SNMP Reported In Release: FOS6.3.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000462242 Technical Severity: Medium Summary: Inconsistent enforcement of RBAC permissions for config commands run in interactive mode and in non-interactive mode Symptom: For Chassis and LF user role as "user", config commands(configshow/configdownload/configupload) trigger "RBAC permission denied.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000466750 Technical Severity: Medium Summary: Misleading last updated time in Switch Events and Switch Information tab. Symptom: In Switch Events and Switch information tab, the last updated time shows the Host time instead of showing the Switch time. Risk of Fix: High Probability: Low Feature: WebMgmt Function: Switch Explorer/Switch View Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000468152 Technical Severity: High Summary: after zone change nszonemember missing members and ports show HARD_PORT dhp bit set: 1 Symptom: A zoning change (removal) was made from the core switch at which time the name server stopped responding, causing outages on the hosts. Workaround: Allow 5 minutes delay between cfgsave and cfgenable command Risk of Fix: Low Probability: Low Feature: FOS Software Function: Fabric Services FOS7.0.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000469915 Technical Severity: High Summary: nscamshow report state is unknown for remote switches Symptom: nsshowall fails to display PIDS for switches that are connected using long distance E_Ports. Risk of Fix: Low Probability: Low Feature: FOS Software Function: Fabric Services Reported In Release: FOS6.4.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000471723 Technical Severity: High Summary: FLOGI ACC not being sentfrom switch in AG mode during N_Port offline/online Symptom: redundant HBA port fails to come online when N_Port is offline/online Risk of Fix: Low Probability: Low FOS Software Feature: Function: Access Gateway Reported In Release: FOS7.0.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000472858 Technical Severity: High Summary: A learning flow does not monitor all real flows on the egress port. Symptom: A learning flow, defined on an egress port with both generator and monitor features specified and also has either srcdev or dstdev option as '*' will monitor less number of flows than actual number of flows going through the egress port. This will only happen when the number of real flows exceeds 32.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000473940 Technical Severity: High Summary: C2-1013 Duplicate rte_tbl_select detected! observered after upgrade. Symptom: After upgrading from v6.4.3b to v7.0.2c several ports observed C2-1013 (Duplicate rte_tbl_select detected!) messages. Workaround: None currently. Risk of Fix: Low Probability: Low Feature: FOS Software Function: ASIC Driver FOS7.0.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000475599 Technical Severity: Medium Summary: mapssam --show does not show port type of N_port trunks for FOS switch ports attached to access gateway Symptom: Customer cannot identify port type of N_port trunks in AG using CLI "mapssam --show" Risk of Fix: Low Probability: Medium Feature: Advanced Monitoring Services Function: Other Reported In Release: FOS7.2.