Brocade Fabric OS Troubleshooting and Diagnostics Guide v7.1.0 (53-1002751-01, March 2013)

104 Fabric OS Troubleshooting and Diagnostics Guide
53-1002751-01
Diagnostic Port (D_Port)
10
Example
Use the switchShow command to see D_Port information as in the following example.
switch:admin> switchshow
switchName: switch_10
switchType: 109.1
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 1
switchId: fffc01
switchWwn: 10:00:00:05:33:13:2f:b4
zoning: OFF
switchBeacon: OFF
FC Router: OFF
Allow XISL Use: ON
LS Attributes: [FID: 10, Base Switch: No, Default Switch: No, Address Mode 0]
Index Port Address Media Speed State Proto
==============================================
24 24 010000 id N16 Online FC D-Port Loopback->Port 24
26 26 010200 id N16 Online FC D-Port segmented,(D-Port mode
mismatch)
33 33 010300 id N8 Online FC D-Port 10:00:00:05:33:13:2f:b5
Example
Use the portCfgShow command to see which ports are D_Port enabled.
switch:admin> portcfgshow
Ports of Slot 0 24 26 27
----------------------+---+---+---
Octet Speed Combo 1 1 1
Speed AN AN AN
AL_PA Offset 13 .. .. ..
Trunk Port ON ON ON
Long Distance .. .. ..
.....
.....
Mirror Port .. .. ..
Rate Limit .. .. ..
Credit Recovery ON ON ON
Fport Buffers .. .. ..
Port Auto Disable .. .. ..
CSCTL mode .. .. ..
D-Port mode ON ON ON
Compression .. .. ..
Encryption .. .. ..
FEC ON ON ON
Fault Delay 0 0 0
where AE:QoSAutoEnable, AN:AutoNegotiate, ..:OFF,