HP ProLiant ML310 Storage Server user guide (AG620-96001, November 2006)

Conguring additional storage involves creating arrays, logical disks, and volumes. Table 6 shows the
general task areas to be performed as well as the utilities needed to c on g ure storage for an HP Sm a rt
Array-based storage server .
Table 6 Tasks and u tilities needed for storage server conguration
Task Storage management utility
Create disk arrays
HP Array Conguration Utility or Storage Manager
Create logical disks from the array space HP Array Conguration Utility or Storage Manager
Verify newly created logical disks
Windows Disk Management
Create a volume on the new logical disk Windows Disk Management
NOTE:
The type of conguration may not apply to all supported storage components and serves only as an
exa mple providing basic guidance.
Create disk arrays—On storage servers with congu rable storage, physical disks can be
arranged as RAID arrays for fault tolerance and enhanced performance, and then segmented into
logical disks of appropriate sizes for particular storage needs. These logical disks then become
the volumes that appear as drives on the storage server.
CAUTION:
The rst two logical dri ves ar e congured for the storage server operating system and should not
be altered in any manner.
The fault tolerance level depends on the amount of disks selected when the array was created. A
minimum of t wo disks is required for RAID 0+1 conguration, three disks for a RAID 5 con guration,
andfourdisksforaRAID6(ADG)conguration.
Create logical disks from the array space — Select the desired fault tolerance, stripe size, and
size of the logical disk.
Verify newly created logical disks—Verify that disks m atching the newly created sizes are
displayed.
Create a volume on the new logical disk—Select a drive letter and enter a volume label, volume
size, allocation unit size, and mount point (if desired).
NOTE:
Do not tamper with the “DON’T ERASE” or local C: volume. These are reserved volumes and must
be maintained as they exist.
Storage management utilities
The storage management utilities pre-installed on the storage server include the HP Array Conguration
Utility (ACU).
Array management utilities
Storage d evices for RAID a rrays and LUNs are created and managed using the array mana gement
utilities mentioned previously. For HP Smart Arrays use the A CU.
HP ProLiant ML310 Storage Server