10.5 HP StoreVirtual Storage User Guide (AX696-96269, March 2013)

14. If this is the only Failover manager you are installing, select No, I am done and click Next.
NOTE: If you want to install another Failover Manager, the wizard repeats the steps, using
information you already entered, as appropriate.
15. Finish the installation, reviewing the configuration summary, and click Deploy.
When the installer is finished, the Failover Manager is ready to be used in the HP StoreVirtual
Storage.
After installation, click FindFind Systems in the CMC and enter the Failover Manager IP address
to discover the Failover Manager, and then add it to a management group. See Adding a storage
system to an existing management group” (page 116) for more information.
Installing the Failover Manager for other VMware platforms
1. Insert the DVD in the DVD drive (either the physical HP StoreVirtual VSA and Failover Manager
DVD you received or the DVD you created after downloading the DVD .iso image from the
web).
2. Locate the applicable executable and double-click it to begin.
3. Click Agree to accept the terms of the License Agreement.
4. Click Failover ManagerInstall FOM for other VMware platforms to begin the wizard.
5. Accept the terms of the License Agreement, and click Next.
6. Accept the default location to install the files, or change the location, and click Next.
7. To complete the installation, click Finish.
Configuring the IP address and host name
1. In the VMware application, navigate to the location of the Failover Manager and start the
virtual machine.
2. Wait for the Failover Manager to boot.
3. When the Failover Manager finishes booting, enter Start and press Enter to log in to the
Configuration Interface.
4. On the main menu, press Tab to navigate to Network TCP/IP Settings and press Enter.
5. On the Available Network Devices window, press Tab to navigate to the network interface
and press Enter.
6. On the Network Settings window, press Tab to navigate to the Hostname field. Press Backspace
to erase an entry if necessary. Enter a host name for the Failover Manager.
This host name displays in the CMC only. It does not change the name of the original .VMX
file or the name of the virtual machine in the VMware interface.
7. Press Tab to navigate to the method for setting the IP address.
If you are entering a static IP address, Gateway is a required field. If you do not have a
gateway, enter 0.0.0.0.
8. Press Tab to navigate to OK and press Enter.
9. Press Enter again to confirm the action.
10. After the settings are configured, press Enter to confirm the IP address change.
11. On the Available Network Devices window, press Tab to navigate to Back and press Enter.
12. On the Configuration Interface, press Tab to navigate to Log Out and press Enter.
After installation, click FindFind Systems in the CMC and enter the Failover Manager IP address
to discover the Failover Manager, and then add it to a management group. See Adding a storage
system to an existing management group” (page 116) for more information.
128 Working with managers and quorum