HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
Main error code descriptions
Table 41 Main error codes
Details and solutionDescriptionError code
Power-cycle the unit and retry the operation.Cannot initialize bar code reader80
No response from bar code reader81
Power-cycle the unit and retry the operation.
Update the firmware to the latest version.
Power-cycle the unit and retry the operation.No response from EEPROM on robotic controller82
Robotic controller generic problem83
Power-cycle the unit and retry the operation.
If the library robotics OR library controller
were just replaced, update the firmware to the
latest version.
If this error occurs right after a firmware
update, update the firmware again — the
robotics firmware may not have been properly
updated the first time.
CAUTION: Never replace the library robotics
and library controller at the same time. Critical
library identification data will be lost.
Setting of gripper
1
motor parameters failed84
Power-cycle the unit and retry the operation.
Setting of slider
2
motor parameters failed85
If the robotics have been replaced, update the
firmware. (MSL8048 and MSL8096 only).
Setting of elevator
3
motor parameters failed86
Update the firmware to the latest version.
Setting of rotation
4
motor parameters failed87
Setting of sled
5
motor parameters failed88
168 Troubleshooting