HP StorageWorks MSL6000 series tape library user guide (231910-009, February 2008)

Troubleshooting128
700C Destination Xchg was Null Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
700D Sending of a cmd failed Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
700E Deactivating a drive that is not attached
(The control task indicates that a request
to deactivate a drive failed because the
drive is not attached.)
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Reseat the drive.
Check cabling.
700F Deactivation of a drive failed
(The control task indicates that a request
to deactivate a drive failed. Reason
unknown.)
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window
Reseat the drive.
Check cabling.
7010 Drive removal failed
(The drive task indicates that a request to
power-down a drive failed. Reason
unknown.)
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
7012 Drive is Active failed
(The drive task indicates that a request to
determine if a drive is executing a host
command failed. Reason unknown.)
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Table 10 Fault Symptom Codes (continued)
FSC Message ERP