MSL5000 and 6000 Series Tape Libraries User Guide
Troubleshooting
164 HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
701A Xchg conversion failed
(Attempted to determine the module
number containing the task that is
returning a command response failed.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
701B Invalid L-drive number to
convert
(Attempted to send a command to a drive,
but the logical drive number is out of
range.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Ensure the drive shows good status
through the drive status window.
701C Invalid P-drive number to
convert
(Attempted to send a command to a drive,
but the physical drive number is out of
range.)
■ Press the Enter button clear the message.
■ Cycle power to the library.
■ Ensure the drive shows good status
through the drive status window.
701D Invalid mod number to convert
(Attempted to send a command to a drive
in a remote module, but the module
number is out of range.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
701E Unknown drive type
(Attempted to show detailed drive status of
a drive whose type is unknown.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Ensure the drive shows good status
through the drive status window.
701F The SCSI response was not
expected
(The command response from the SCSI task
in a remote module was unexpected.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Ensure the drive shows good status
through the drive status window.
7020 The Flash response was not
expected
(The command response from the Flash
task in a remote module was unexpected.)
■ Press the Enter button clear the message.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Ensure the drive shows good status
through the drive status window.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP