HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
Table 41 Main error codes (continued)
Details and solutionDescriptionError code
magazine and then the lower-left magazine was
replaced with a one-slot mailslot magazine.
with the new mailslot configuration. Note: You
will need to reconfigure your backup software.
If the issue continues, inspect the magazine
for damage and missing light pipes or
magazine prism pieces (clear plastic pieces
in each slot).
Retry the backup with a token with space for
more keys.
NOTE: Each token can hold 100 keys. Keys
cannot be overwritten or deleted; only unique
keys will be written to the token.
Key server token backup not successful (not
enough available space on target token)
E1
Update the library firmware to the current
version.
Unsupported hardware detected. Some hardware
that is connected to the library requires updated
library firmware.
E2
Error during key server token backup; backup
process unsuccessful.
E3
Retry the backup with a different token.
If the error occurs again, contact HP customer
support.
Drive firmware does not support encryption.E4
Ensure that all tape drives that support
encryption (LTO-4 and later generations) are
at the minimum firmware required for the
Encryption Kit:
Ultrium 1760 SCSI: W22W
Ultrium 1760 SAS: U26W
Ultrium 1840 SCSI: B45W
Ultrium 1840 SAS: H44W
If necessary, update the tape drive firmware
to the current version.
When encryption is enabled with the
Encryption Kit, ensure that all tape drives in
the logical library support encryption (LTO-4
and later generations). When possible, avoid
including LTO-2 and LTO-3 tape drives in a
logical library when encryption is enabled.
Drive generation does not support encryption.E5
Key Server Token restore process did not
complete, Key Server Token restore failed.
E6
Retry the operation on the same key server
token.
Retry the operation on a new key server token.
Incorrect Key Server Toke Type. Token not
supported within this device.
E7
Verify that the USB device is an HP key server
token from the HP 1/8 G2 & MSL Encryption
Kit.
Retry the operation on a new key server token.
The first MSL2024 libraries do not support the
Encryption Kit. Contact your HP service
representative to upgrade your MSL2024
chassis to a newer version.
Encryption Kit not available due to incompatible
library controller.
E8
Drive exceeded temperature specificationF0
Check ambient temperature to ensure that it
is within operating specifications.
Error codes 177