HP StorageWorks 2300 Family Modular Smart Array CLI reference guide (500912-002, July 2010)

134
Add'l Data
Additional data such as fan speed (RPM), temperature (Celsius), voltage, or slot address
Example Show enclosure status for a system with a controller enclosure and an MSA70 drive enclosure:
# show enclosure-status
Chassis Vendor Product ID CPLD EMP A BUS:ID Rev EMP B BUS:ID Rev
WWPN Status Health
--------------------------------------------------------------------------
3CL816C013 vendor product 8 0:31 1022 1:31 1022
500C0FF00000133C OK OK
--------------------------------------------------------------------------
Type # Status FRU P/N FRU S/N Add'l Data
--------------------------------------------------------------------------
FAN 01 OK PN SN speed=5980
FAN 02 OK PN SN speed=6070
PSU 01 OK PN SN --
PSU 02 OK PN SN --
Temp 01 OK PN SN temp=37
...
Temp 04 OK PN SN temp=33
Voltage 01 OK PN SN voltage=11.86V
...
Voltage 10 OK PN SN voltage=3.49V
Disk 01 OK PN SN addr=0
Disk 02 OK PN SN addr=1
...
--------------------------------------------------------------------------
Chassis Vendor Product ID CPLD EMP A BUS:ID Rev EMP B BUS:ID Rev
WWPN Status Health
--------------------------------------------------------------------------
N/A HP MSA70 N/A 1:63 2.18 0:63 2.18
50014380004C3F80 OK OK
--------------------------------------------------------------------------
Type # Status FRU P/N FRU S/N Add'l Data
--------------------------------------------------------------------------
FAN 01 OK N/A N/A speed=5400
...
FAN 04 OK N/A N/A speed=5400
PSU 01 OK N/A N/A --
PSU 02 OK N/A N/A --
Temp 01 OK N/A N/A temp=37
...
Temp 04 OK N/A N/A temp=35
Disk 01 OK N/A SN --
...
Disk 25 OK N/A SN --
--------------------------------------------------------------------------
See also show enclosures