HP MSA 1040 CLI Reference Guide (762782-001, March 2014)

362 XML API basetype properties
auto-write-through-trigger
This basetype is used by show auto-write-through-trigger.
Table 11 auto-write-through-trigger properties
Name Type Description
controller-
failure
string Shows whether the cache policy will change from write-back to write-through
when a controller fails.
Disabled: The controller failure trigger is disabled. This is the default.
Enabled: The controller failure trigger is enabled.
super-cap-
failure
string Shows whether the cache policy will change from write-back to write-through
when the supercapacitor that provides backup power for cache is not fully
charged or fails.
Disabled: The supercapacitor failure trigger is disabled.
Enabled: The supercapacitor failure trigger is enabled. This is the default.
compact-flash-
failure
string Shows whether the cache policy will change from write-back to write-through
when CompactFlash memory is not detected during POST (Power-On Self-Test),
fails during POST, or fails during controller operation.
Disabled: The CompactFlash failure trigger is disabled.
Enabled: The CompactFlash failure trigger is enabled. This is the default.
power-supply-
failure
string Shows whether the cache policy will change from write-back to write-through
when a power supply fails.
Disabled: The power-supply failure trigger is disabled. This is the default.
Enabled: The power-supply failure trigger is enabled.
fan-failure string Shows whether the cache policy will change from write-back to write-through
when a fan fails.
Disabled: The fan failure trigger is disabled. This is the default.
Enabled: The fan failure trigger is enabled.
temperature-
exceeded
string Shows whether the system will shut down a controller when its temperature
exceeds the critical operating range.
Disabled: The over-temperature trigger is disabled. This is the default.
Enabled: The over-temperature trigger is enabled.
partner-notify string Shows whether the partner controller will be notified when a trigger condition
occurs.
Disabled: Notification is disabled; the partner controller will continue
using its current caching mode. This is the default.
Enabled: Notification is enabled; the partner controller will change to
write-through mode for better data protection.
auto-write-back string Shows whether the cache policy will change from write-through to write-back
when the trigger condition is cleared.
Disabled: Auto-write-back is disabled.
Enabled: Auto-write-back is enabled. This is the default.