HP Capacity Advisor 6.2 Users Guide

Table H-2 Warning Messages in Capacity Advisor (continued)
To correctProbable causeMessage
The most recent sample is kept.More than one sample imported
with capprofile has the same
time stamp.
Values at duplicate sample time
sample_time replace previous values for
this time.
On the CMS managing system_name,
open the HP SIM “All Systems” list,
click the system name to go to the HP
SIM System Page.
Workload on the utilization
provider on system_name is not
known to VSE. No utilization data
is collected for this unknown
workload.
Warning: Ignoring unknown workload
workload_name on system_name
Redefine the workloads so that their
utilization limits fall within the
resource allocation for the system.
The sum of workload utilizations
exceeds system utilization.
Warning: Overlapping workload
definitions detected on system_name.
Install a version of the WBEM Services
Core Product that is 2.00.08 or later.
capcollect relies on WBEM to
report the local time on a system,
but Version 2.00.07 of the WBEM
Services Core Product for HP-UX
reports the local time incorrectly.
Messages that do not indicate a
time difference of about an hour
and for which actual times on the
servers are not an hour apart, are
not likely to be caused by the
wrong WBEM version.
Warning: the system clock on
system_name is ~60 minutes, ss seconds
ahead of the system clock on the CMS;
this may render the utilization data
unusable for planning purposes. If the
time on the managed node is correct, the
node's version of 'HP WBEM Services for
HP-UX' may be older than the minimum,
A.02.00.08.
Ensure that clocks on systems in the
scenario are synchronized to the clock
on the CMS system.
When systems are used together
in a scenario, Capacity Advisor
assumes that the time axis of the
utilization graphs for all systems
is the same. The time axis is
obtained from the system clock
on the system where the
utilization data is gathered. If the
system clock is not synchronized
with the other systems and with
the CMS, the Capacity Advisor
summed utilization traces may
not be correct. This error message
is issued if the time difference
between the system for which
data is collected and the CMS is
more than 15 minutes.
Warning: the time difference of nnn
seconds between the system clock on
system_name and the system clock on the
CMS may render the utilization data
gathered unusable for planning
purposes.
HP Smart Solver error messages
In situations where the Smart Solver is unable to produce a solution, one or more error messages
are displayed. Solver error messages are shown in red text on the user interface screen and
describe the issues that prevent a solution from being found.
When available systems lack sufficient capacity
When workloads cannot be placed on any system because the available systems lack sufficient
capacity in one or more resources, the workloads are excluded from the computation and listed
in the Smart Solver Excluded Systems table. A summary line is included that reports the
minimum system capacity required to place the workload(s).
180 Capacity Advisor messages