HP Capacity Advisor 6.2 Users Guide
Table H-2 Warning Messages in Capacity Advisor (continued)
To correctProbable causeMessage
Synchronize the managed node clock
to the CMS system clock.
Capacity Advisor cannot analyze
utilization across multiple
systems or servers when system
clocks (and therefore, data
timestamps) are not
synchronized.
Sample time sample_time is not aligned
to hour intervals.
The system or server is running
an operating system unsupported
by VSE.
Skipping system_name — collection from
the some_operating_system operating
system is not supported.
From the HP SIM “All Systems” page,
click the system name to go to the HP
SIM System Page. On the “identify”
tab, click the + next to “Product
Description” to expand it. If the System
Type is “unknown” or “unmanaged,”
capcollect cannot collect data from
that system. Change the System Type
to “server.”
HP SIM has not discovered
enough information about this
system for capcollect to be
able to collect data from the
system. capcollect requires
that the System Type attribute has
the value “server” to collect from
a system.
System system_name has incomplete
system information. Check the system's
status in HP SIM.
Set up the trusted certificate by
manually installing the system's
certificate into the HP SIM Trusted
System Certificate List.
See message text.system_name: HP SIM requires trusted
certificates for managed systems but no
trusted certificate exists for this system.
Install the WBEM utilization provider
on the system.
See message text.system_name: The Utilization WBEM
Provider is not installed.
Correct the global or system protocol
settings for the affected system in HP
SIM. You may need to rerun discovery
to have the settings take effect.
The capcollect command
cannot use the WBEM credentials
provided by HP SIM, perhaps
because of recent changes to the
user ID or password.
system_name: The WBEM credentials
provided by HP SIM were not accepted
by the WBEM server.
On the managed system, execute the
command
/opt/wbem/sbin/cimserver
The WBEM provider on the
system is not running and should
be restarted.
system_name: The WBEM server is not
running and should be restarted.
See message text.See message text.system_name: Upgrade the Utilization
Provider on this system to version
A.01.06.00.00 or later.
Run vseassist to troubleshoot
connection issues.
A network or system problem
prevents contact with the WBEM
server.
system_name: Unable to contact the
WBEM server. See the capcollect(1M)
manual page.
Run vseassist to troubleshoot
connection issues.
system_name: System information is not
available from the WBEM provider.
Collection from this system cannot
proceed until this situation is corrected.
If you prefer not to use the method
described in the message, change the
value for the CMS_HOSTNAME
property in the vseprefs.props file
from localhost to some other name that
resolves to the IP address of the CMS.
See message text.The Name Resolution Service could not
resolve localhost on the CMS. To correct
this, make sure that either the name
localhost can be resolved on the CMS or
change the CMS_HOSTNAME setting in
/etc/opt/vse/vseprefs.props to
a hostname for the CMS that can be
resolved. See the hosts(4) and
nsswitch.conf(4) manual pages.