HP Capacity Advisor 6.2 Users Guide

Table H-2 Warning Messages in Capacity Advisor
To correctProbable causeMessage
Check for advisements and take
corrective action if desired.
Appears at the end of output if
any warnings were issued.
1 warning issued
or
n warnings issued
Overlapping samples are automatically
ignored or invalidated in Capacity
Advisor. Import the data again, taking
care to designate date ranges that do
not overlap.
Samples imported with
capprofile that overlap in time
cannot be interpreted.
A series of overlapping samples begins
at time sample_time. The overlapping
samples starting at this time are ignored.
Discover the system from an HP SIM
CMS running on a Microsoft Windows
system and collect data from there.
Collection from VMware and
MSVS Virtual Machines is only
supported from a Windows HP
SIM CMS.
Collection from system_name is not
supported on an HP-UX CMS.
The improperly formatted values will
be automatically marked as invalid,
and will not be included in Capacity
Advisor reports.
Some formatting errors can be
manually corrected. See the
capprofile(1M) command reference page
for format examples.
Use a profile viewer to determine if the
sample contains a sufficient number
of valid data points to provide a
meaningful report.
A sample line in the file imported
with capprofile contains
values that are improperly
formatted.
Improperly formatted sample values at
time sample_time have been ignored.
See “Out-of-memory errors in the Java
heap” (page 170).
See “Out-of-memory errors in the
Java heap” (page 170).
Java Heap Space. Please see the HP
Capacity Advisor User's Guide for more
information on this issue and possible
solutions.
The missing samples will be
automatically marked as invalid and
will not be included in Capacity
Advisor reports. Use a profile viewer
to determine if the sample contains a
sufficient number of valid data points
to provide a meaningful report.
Samples imported with
capprofile are missing for one
or more sample intervals.
Missing sample for 1 time interval at time
sample_time.
or
Missing samples for n time intervals at
time sample_time.
The negative samples will be
automatically marked as invalid and
will not be included in Capacity
Advisor reports. Use a profile viewer
to determine if the sample contains a
sufficient number of valid data points
to provide a meaningful report.
A sample imported with
capprofile contained a
negative value for the value of a
metric.
Negative sample value at time
sample_time has been ignored.
Ensure that the CMS has access to
WBEM. Run vseassist to
troubleshoot connection errors.
CMS access to WBEM, using
Bastille, ipf, or other means, has
been shut down.
No systems are available from HP SIM
in the “HPVSE” collection.
Add the required credentials to the
systems where you plan to run
Capacity Advisor, or run the
cimserver process. You can also run
vseassist to troubleshoot connection
errors.
Either no WBEM credentials have
been entered in HP SIM or HP
SIM could not successfully use the
credentials entered. The latter can
happen when acimserver
process is not running on the
system.
No WBEM credentials are available for
system "system_name”. Please verify
that a valid WBEM account and
password for this system are configured
in HP SIM (Options->Protocol
Settings->Global Protocol Settings).
Command warning messages 177