HP PCL/PJL reference - Printer Job Language Technical Reference Manual
6-30 Environment Commands EN
LINETERMINATION Sets the default PCL line termination
value:
0: CR = CR, LF = LF, FF = FF (no
change)
1: CR replaced by CR-LF, LF = LF, FF =
FF
2: CR = CR, LF replaced by CR-LF,
FF replaced by CR-FF
3: CR replaced by CR-LF, LF replaced
by CR-LF, FF replaced by -->CR-FF
0, 1, 2, 3
PITCH Pitch of the default font in units of
characters per inch (the default font
must be a fixed-pitch scalable font). The
pitch value can be specified to two
decimal places.
0.44, 0.45, . . .
99.99
PTSIZE Height of the default font in units of
points (the default font must be a
proportional scalable font). The point
size is significant to a quarter of a point.
4.00, 4.25, . . .
999.75
SYMSET Symbol set. (If the currently selected
SYMSET is WIN3.1J, then the default
PCL text parsing method is set to
Shift-JIS compatible parsing [WIN3.1J
is only available in the HP LaserJet 4PJ,
the HP LaserJet 4LJ Pro, and the HP
LaserJet 4V/4MV when ESC/P is
installed].)
On the HP LaserJet 4LC printer, if the
SYMSET is GB2312 the default PCL
text parsing method is set to
GB-compatible parsing. [GB2312 is
only available in the HP LaserJet 4LC
printer.]
ROMAN8, ISOL1,
ISOL2, ISOL5,
ISOL6, PC775,
PC8, PC8DN,
PC850, PC852,
PC8TK, PC1004,
WINL1, WINL2,
WINL5, DESKTOP,
PSTEXT,
MSPUBL, MATH8,
PSMATH, PIFONT,
LEGAL, ISO4,
ISO6, ISO11,
ISO15, ISO17,
ISO21, ISO60,
ISO69, WIN30,
WIN31J, WINBALT,
GB2312, MCTEXT
PCL-Specific Variables (continued)
Variables Description
Sample Value
Range