5.6.2 HP IBRIX X9000 Release Notes
The default value of this command is 900; the value is in seconds. A higher value reduces the
probably of all components toggling from Up to Stale and back to Up because of the conditions
listed above, but will increase the time before an actual component failure is reported.
HP Insight Remote Support
• In certain cases, large number of error messages such as the following appear in /var/log/
hp-snmp-agents/cma.log:
“Feb 08 13:05:54 x946s1 cmahostd[25579]: cmahostd: Can't update OS
filesys object: /ifs1 (PEER3023)”
This error message occurs because the file system exceeds <n> TB. (This situation will be corrected
in a future release.) To disable logging, edit the script /opt/hp/hp-snmp-agents/server/
etc/cmahostd and remove the option -l <logname>. Then restart the agents using service
hp-snmp-agents restart.
If you want to keep logging enabled, be aware that the log messages occur frequently, and you
will need to monitor and clean up the log file regularly to avoid filling the file system.
• If FQDN resolution is not configured properly for the hosts, the following error appears when
hpsmhd is restarted:
Could not reliably determine the server's fully qualified domain name,
using <ip> for ServerName
To configure FQDN resolution, use either the /etc/hosts file or the Domain Name Service.
• After a file serving node is restored with the Quick Restore DVD, you will need to reconfigure
remote support on the node.
• If SNMP is logging excessively, add the following command to the file /etc/sysconfig/
snmpd.options to stop the logging:
OPTIONS="-LS 0-4 d -Lf /dev/null -p /var/run/snmpd.pid -a"
To enable the default SNMP logging, update the following command in the file /etc/sysconfig/
snmpd.options:
# OPTIONS="-LS 0-4 d -Lf /dev/null -p /var/run/snmpd.pid -a"
Add a pound sign in front of the command and save the file. Then restart the snmp service:
service snmpd restart
• When installing IRSA A.05.50 or IRSS A.05.50 on Windows Server 2008, install it to a non-default
location (not under Program Files).
• Onboard Administrator is discovered as unknown on IRSS. After Onboard Administrator discovery,
manually enter the following details:
◦ Select System Subtype as ProLiant Onboard Administrator.
◦ Enter the Entitlement serial number (this is same as the X9000 enclosure product number).
◦ Enter the Entitlement product number (this is same as the X9000 enclosure product number).
16 Workarounds