HP StorageWorks EVA Virtualization Adapter administrator guide (5697-0177, October 2009)
Table Of Contents
- EVA Virtualization Adapter administrator guide
- Table of Contents
- 1 Overview of HP EVA Virtualization Adapter
- 2 Configuring SRM and the HP EVA disk array
- 3 Installing and removing HP EVA Virtualization Adapter
- 4 Failover and failback with SRM
- 5 Troubleshooting HP EVA Virtualization Adapter
- HP StorageWorks EVA disk arrays do not appear in Site Recovery Manager
- HP StorageWorks EVA Virtualization Adapter does not install
- Virtual machines do not start at recovery site after failover.
- Site Recovery Manager timeout failure in large array configurations
- Virtual machines do not start at recovery site during the test failover test.
- Error messages
- SRM log
- EVA log
- HP EVA Virtualizaton Error Messages
- 6 Reference
- Glossary
- Index
5. Verify that the array managers are configured by looking for the following information in the
Configure Array Managers window:
• Array Manager Info
• Local and remote array information
• LUN count (equals the number of replicated LUNs on each EVA)
6. Verify the array mangers have been configured for both protected and recovery sites, and rep-
licated datastores in the Review Replicated Datastores window.
Create protection groups
You are ready to create protection groups in the protected site using SRM. Protection groups (containing
virtual machines) fail over together to the recovery site during test and recovery. For more information
on creating protection groups, see the VMware Site Recovery Manager Administration Guide.
Configuring SRM and the HP EVA disk array18