HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

Checking timeo
ut values
The key timeout setting in the registry a t HKEY_LOCAL_MACHINE/SYSTEM/
CurrentContr
olSet/Disk/TimeoutValue should be set to 3c (60 seconds)
HP-UX
CAUTION:
BecauseHP-UXsupportsbootacrossFibreChannelSAN,anychangetodefaultSCSItimeoutsonthe
HP-UXhostmaycausecorruptionandmakethesystemunrecoverable.
Default timeout values
Sdisk timeout: 30 seconds
(LVM) lvol timeout: 0 seconds
Checking timeout values
Device within a L VM volume group: pvdisplay /dev/dsk/cxtxdx
lvol physical volume with an LVM group: lvdisplay /dev/vgxx/lvolx
Changing timeout values
Pvchange -t (seconds) /dev/dsk/cxtxdx
Linux
The follow ing conguration recommendations apply to both RedHat and SuSE.
QLogic Driver parameters (failover enabled):
qdepth = 16
port_down_retr y_count = 30
login_retry_count = 30
failover = 1
load_balancing = 1
excludemodel = 0x0
auto_restore = 0xA6
QLogic Driver parameters (single path) :
qdepth = 16
port_down_retr y_count = 64
login_retry_count = 30
failover = 1
load_balancing = 1
excludemodel = 0x0
auto_restore = 0xA6
Emulex Driver parameters (single p ath)
HPELXLPFC=y
nodev_timeout=60
qdepth=30
30
Pre-upgrade tasks