3. Connect the VRM cables to the backplane.
NOTE:
The cables are keyed and are different in size, to
prevent connecting to the wrong port.
4. Reinstall the two power supplies, making sure to push the module
into the enclosure until a click is detected when fully seated.
5. Secure the top access panel on the enclosure.
NOTE:
Place the torx tool back inside the enclosure chassis,
on top of the I/O module housing, for future use.
6. Reinstall the enclosure in the rack.
7.
WARNING!
Reinstall drives in the same slot locations.
With the drive lever in the open position, reinsert drives fully into
each bay, pressing on the lever to secure each drive, remove any
labels added to mark the drives.
NOTE:
Reinstall drives in the same slot locations.
8. Reattach the cabling to the enclosure components.
9. Press the On/Standby button on the power UID bezel and hold it
down long enough to power up the enclosure. Wait for the enclosure
to complete the Power On Self Tests (POST).
10. Restart all servers with access to the disk enclosure, to ensure that
the storage is discovered properly.
Verifying proper operation
NOTE:
Wait three minutes after powering up the enclosure for the
system to check component status.
Verify the enclosures status LEDs as described in Verifying component
failure.
Returning the failed component
Follow instructions shipped with the replacement part.