swFCPortOpStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4
5
Values Possible values are:
• noCard (1) No card is present in this switch slot.
• noTransceiver (2) No Transceiver module in this port (Transceiver is the generic name for GBIC,
SFP, and so on).
• laserFault (3) The module is signaling a laser fault (defective GBIC).
• noLight (4) The module is not receiving light.
• noSync (5) The module is receiving light but is out of sync.
• inSync (6) The module is receiving light and is in sync.
• portFault (7) The port is marked faulty (defective GBIC, cable, or device).
• diagFault (8) The port failed diagnostics (defective G_Port or FL_Port card or motherboard).
• lockRef (9) Port is locking to the reference signal.
• validating (10) The module is being validated.
• invalidModule (11) The module is invalid.
• unknown(255) The module is unknown.
swFCPortOpStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4
The operational status of the port.
Values Possible values are:
• unknown (0) The port module is physically absent.
• online (1) User frames can be passed.
• offline (2) No user frames can be passed.
• testing (3) No user frames can be passed.
• faulty (4) The port module is physically faulty.
swFCPortAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5
The desired state of the port. A management station might place the port in a desired state by
setting this object accordingly.
Based on the port status, this OID returns one of the following:
• Online -- When queried port is online.
• Offline -- When queried port is offline.
• Faulty -- When port is in faulty state.
This OID is settable, the following values can be used to set:
• Online -- To change port's state to Online.
• Offline -- To change port's state to Offline.