Fabric OS MIB Reference v6.4.0 (53-1001768-01, June 2010)
Fabric OS MIB Reference 155
53-1001768-01
swFault 1.3.6.1.4.1.1588.2.1.1.1.0.1
5
Refer to the Fabric OS Command Reference and the snmpMibCapSet command on how to enable
or disable the sending of traps from the various MIBs.
The swSsn variable is optional in trap messages.
The swGroupName, swGroupType, and swGroupMemPos variables are optional trap messages in
v2.6.x. The swGroupName, swGroupType, and swGroupMemPos variables are not supported in
Fabric OS v4.x and above.
Because Fabric OS releases prior to v5.2.0 used to show the Enterprise Field in the swTraps from
the sysObjectID (set using config variable "snmp.sysObjectID"), the Enterprise field will not always
be resolved to "sw". If the sysObjectID is changed by user the Enterprise field in the trap will show
some unresolved value.
To resolve this issue, beginning with the v5.2.0 release the SNMP configuration variable
snmp.trapEnterpriseFlag lets you define the way that the Enterprise field displays.
Select either the previous behavior in which the Enterprise field is taken from sysObjectID or the
new behavior in which the value in the Enterprise field will always be "sw":
• Set the value of this variable to 0, to use the sysObjectID.
• Set the value to 1 to use the fixed enterprise value, "sw" (1.3.6.1.4.1.1588.2.1.1.1.).
swFault 1.3.6.1.4.1.1588.2.1.1.1.0.1
This trap is no longer generated.
Enterprise sw
Variables “swDiagResult 1.3.6.1.4.1.1588.2.1.1.1.1.20”
“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10”
A swFault is generated whenever the diagnostics detect a fault with the switch.
“swFabricSegmentTrap
1.3.6.1.4.1.1588.2.1.1.1.0.10”
on page 160
10 The trap to be sent for tracking
segmentation.
Refer to the Fabric OS Command Reference
and the snmpConfig command for more
information.
“swExtTrap
1.3.6.1.4.1.1588.2.1.1.1.0.11”
on page 160
11 The trap adds the SSN binding to the traps
if it is enabled.
Refer to the Fabric OS Command Reference
and the snmpConfig command for more
information.
TABLE 14 SW-MIB traps (Continued)
Name Specific When Configure
#TYPE Switch is faulty.
#SUMMARY Faulty reason: %d and SSN is #%s
#ARGUMENTS 0, 1
#SEVERITY Critical
#TIMEINDEX 1
#STATE Nonoperational