Problem Resolution
An error message with the following text
displays:
Real Time statistics collection has failed.
Please see master log for details.
3 To collect GigE port and FCIP statistics, you must enable the FCIP-MIB capability.
Verification and Troubleshooting
To verify that FCIP-MIB capability is enabled, use the following command from the
switch CLI:
FCRRouter:admin> snmpconfig --show mibcapability
FCIP-MIB: YES
To enabling FCIP-MIB capability, use the following command from the switch CLI:
FCRRouter:admin> snmpconfig --set mibcapability
FA-MIB (yes, y, no, n): [yes]
FICON-MIB (yes, y, no, n): [yes]
HA-MIB (yes, y, no, n): [yes]
FCIP-MIB (yes, y, no, n): [yes]
ISCSI-MIB (yes, y, no, n): [yes]
4 To collect FCIP or GE statistics, you must configure SNMPv3 credentials in the
Address Properties dialog box - SNMP tab.
Verify that the SNMPv3 credentials are valid. When you discover a switch using
‘admin’ as the v3 credentials, a new user (for example, User 6) is created with the
SNMP user name ‘admin’. To verify the SNMP user credentials, use the following
command from the switch CLI:
sw1:FID128:admin> snmpconfig --show snmpv3
SNMPv3 USM configuration:
User 1 (rw): snmpadmin1
Auth Protocol: noAuth
Priv Protocol: noPriv
User 2 (rw): snmpadmin2
Auth Protocol: noAuth
Priv Protocol: noPriv
User 3 (rw): snmpadmin3
Auth Protocol: noAuth
Priv Protocol: noPriv
User 4 (ro): snmpuser1
Auth Protocol: noAuth
Priv Protocol: noPriv
User 5 (ro): snmpuser2
Auth Protocol: noAuth
Priv Protocol: noPriv
User 6 (ro): admin
Auth Protocol: noAuth
Priv Protocol: noPriv