Brocade Fabric OS Command Reference Manual Supporting Fabric OS v7.0.0 (April 2011)
Fabric OS Command Reference 563
53-1001764-01
perfAddEEMonitor
22
4. Add another EE monitor on port 1 between the Virtual Target SID and the Target DID:
EncryptionSwitch:SecurityAdmin> perfaddeemonitor 1 \
0x0a2001 0x01a000
End-to-End monitor number 1 added.
5. Display the EE monitors on the Encryption Switch:
EncryptionSwitch:SecurityAdmin> perfmonitorshow --class EE 1
There are 2 end-to-end monitor(s) defined on port 1.
KEY SID DID OWNER_APP TX_COUNT RX_COUNT OWNER_IP_ADDR
---------------------------------------------------------------------
0 0x0a0100 0x0a2002 TELNET 0x000000001d914e1c 0x000000002183f0da N/A
1 0x0a2001 0x01a000 TELNET 0x0000000002b5c076 0x0000000006c4fb04 N/A
SEE ALSO perfDelEEMonitor, perfMonitorClear, perfMonitorShow