Each of these topics is discussed in the following sections.
Examining FC port connection
Most hubs and switches have link indicators showing link status. When the interface controller is
connected and powered on, the link indicator appears solid. If it is not, examine the cabling or
connections.
To examine link
s:
Make sure that the library is not running any tasks before disconnecting any cables. D isconnect
and reconnect the FC cable. This procedure causes momentary activity of this indicator as
the link reinitializes.
Make sure tha
t the cable type for the interface controller and the attached hub, H BA, or switch
are similar.
NOTE:
By default, the F C port speed is set to 2 Gbps for the e2400-FC 2Gb interface controller and to 4
Gbps for the e2400-FC 4Gb interface controller. Changes to the FC port speed must be manually
set, such as for 1 Gbps. If set incorrectly and the interface controller is plugged into a Loop or Fabric,
theunitcanreceiveframingerrors,whichcanbefoundinthetracelogs;theber link light will
be off because of the incorrect FC link speed.
Examining the interface controller conguration
To examine the interface con troller conguration,makesurethat:
The interface controller speed is set correctly.
Theconnectiontypeissetcorrectly.
The host is added to Secure Manager in Command View TL and given permission to communicate
with the library.
Examining devices
HP recommends using Command View TL to make sure that the devices are operating correctly.
Examining the host conguration
In some cases, the FC HBA or host device driver may not be working properly. Check the conguration of
these elements.
Check the release notes for the device driver to see if there are any specicissuesorarequired
conguration. Also, make sure that you are using the current version of the HBA driver.
Older applications can have expectations about what constitutes a valid SCSI ID, and thus may not
correctly handle certain mappings. This is not an issue for the operating system or most applications.
However, some applications may exhibit difculties addressing target IDs greater than 15 (16 and
higher). To resolve this situation in a direct-attach conguration, congure the interface c ontroller to use
hard add ressing and set the AL_PA to a value that the HBA can map, with an ID less than 16.
Examining HBA device driver information
Review the HBA device driver Readme.txt le for conguration specics. An HBA may require a
different conguration. HBAs t ypically come with utility programs to view or change their congurations.
Examining serial port conguration
If you have problems connecting to the serial interface, make sure that the c on guration of the terminal or
terminal emulation program is correct.
78
Maintaining the librar y